EN
9
1) Accessories
Check the package to make sure that the
following accessories are included:
• a number of 1-dose and 2-dose
portalters orresponding to the
number of groups;
• replacement 1-dose and 2-dose
lters (one of each);
• 1 tamper;
• 1 blind lter;
• cleaning detergent, for the groups;
• 3 stainless steel braided hoses for
water connecons;
• 1,5 mt of reinforced plasc tubing for
drainage;
• 1 hose clamp;
• 1 TEE Fing.
In order to proceed with installaon, it is
necessary that the following are available:
• Pipes carrying drinking water with a
3/8”G (BSP) end connecon; (3/8”
Compression for USA and Canada)
• Electrical Supply according to the
specicaon of the espresso machine
purchased:
• Single/Three phase 220VAC - 50/60
Hz electrical connecon with ground,
protected socket and approved
interlock switch
• Single phase 200VAC - 50/60 Hz
electrical connecon with ground,
protected socket and approved
interlock switch
• Three-phase, 380VAC - 50 Hz electrical
connecon with neutral + ground, near
the bench on which the machine is
installed and terminang in a suitable
protected vepole socket equipped
with an approved interlock switch
• Waste water drain system.
Note:
• The drinking water mains valve and
the circuit breakers for the electrical
system need to be located in the most
convenient posion for the operator to
access them easily and quickly.
• The machine should be placed on a at
counter and must be placed in sengs
with the following temperatures:
Minimum room temperature: 5°C/41°F
Maximum room temperature:
32°C/89°F
• If the machine has been temporarily
housed in sengs with a room
temperature of less than 0°C/32°F,
please contact a service technician
prior to use.
• Water pressure supply must be
between 2 and 6 bar.
2) Water test kit
In order to enable you to check if your water
supply is within the suggested ranges, La
Marzocco machines will be equipped with
two units of a quick water test kit (see
image below) including 6 test-strips and
instrucon cards.
The parameters that you can measure are
Total Hardness, Total Iron, Free Chlorine,
Total Chlorine, pH & Total Alkalinity,
Chlorides.
Ideally, you should perform a test on the
water BEFORE the water treatment system
and again AFTER the water system in order
WARNING
AT EACH INSTALLATION, THE MACHINE
SHOULD BE EQUIPPED WITH A NEW SET OF
TUBES FOR PLUMBING AND RELATED
GASKETS.