INSTALLER’S MANUAL
SULLY
Page 15 of 43 US
Table 3
Top burners
5000
11000
15000
18000
GAS
Pressure
Natural Gas
6" WC
0.90
1.30
1.45
1.70
L.P. propane
10" WC
0.65
0.90
1.05
1.20
Adjustment of Burner Low Flame (Figure 17) :
After connection or change of gas, it is crucial to modify this
adjustment.
- Remove the control knob. Light the burner, adjust to
minimum setting, then use a small screwdriver to set the
adjusting screw J.
Note: Flame is reduced to ¼ of its size in the minimum
setting, the burner must remain lit when changing from
maximum setting to minimum setting.
Refitting the cooking surface:
When refitting the cooking surface, it is vital to tighten
fastening screws (figures 6 and 7). Failure to do so can cause
distortion of the cooking surface.
OVEN BURNERS:
Dismounting oven burner
Remove the oven baseplate (Fig.18).
CAUTION: when refitting place the base underneath the groove on the fascia (fig.19).
Unscrew the screw K holding the burner (Fig.20).
Remove the tray.
Unscrew the screw L (Fig.21).
Push the burner to the bottom of the oven and lift to remove it.
Table 4
Top burners
5000
11000
15000
18000
GAS
Pressure
Opening / inches
Natural Gas
6" WC
2,5 /
1
/
8
2,5 /
1
/
8
max
7 /
1
/
4
L.P. propane
10" WC
3,5 /
1
/
8
max
max
max
Fig. 19
Fig. 18
Fig. 20
K
Fig. 17
J
Fig. 21
L

Related product manuals