18
6.2 Gas Requirements
DANGER
Improper use of gas can cause death or serious injury.
Consult a professional if you are unsure of proper gas safety.
This machine requires the use of Oxygen (O2) and Nitrogen (N2) gas for proper use. We
recommend having a six (6) pack of each tank.
6.2.1 Liquid Gas
If you decide to use liquid O2 (Oxygen) or liquid N2 (Nitrogen) you will need a vaporizer as well.
• With liquid oxygen, a vaporizer must be added to heat the liquid to a normal temperature
gaseous state. The high-pressure liquid bottle withstands 4.5MPA, the vaporizer withstands
4.5MPA, flow rate: 1.0m3 / min, output pressure: 2.0MPA.
• With liquid nitrogen, a vaporizer must be added to heat the liquid to a normal temperature
gaseous state. High pressure liquid bottle withstands 4.5MPA, vaporizer withstands 4.5MPA,
flow rate: 1.0 cubic meters / minute, output pressure: 3.0MPA.
6.2.2 Gas Regulators
• Gas Regulators (single stage regulator required, dual-stage optional)
o Oxygen needs to be capable of 150 PSI
o Nitrogen needs to be capable of 300 PSI
6.3 Tools Needed
The tools needed for setup and assembly are:
• Crowbar
• Forklift or floor jack
• Short 5mm Allen key
• Long 5mm Allen key
• Crescent wrench
• Scissors or cutting tool
• Six (6) gallons (23 liters) of distilled water
• Zip ties