Lists the components included in the MR insert option kit.
Details technical specifications of the MR insert probe option.
Guides the user through configuring the MR software for hardware.
Explains the requirement and installation of the MR software key.
Describes the procedure to switch between VSM and MR operational modes.
Provides instructions for safely exchanging samples in the MR insert.
Details the steps for physically installing the MR insert probe.
Instructions for connecting the necessary cables to the MR insert.
Guide to installing and adjusting the MR head lock for proper VSM head suspension.
Steps to connect the MR insert probe to the VSM head.
Overview of operating the MR software, including its interface segments.
Procedure to zero the gaussmeter probe for accurate measurements.
How to create a file for storing sample identification information.
Explains how to build measurement sequences using control and experiment steps.
Describes basic commands for performing measurements like Go to Angle, Go to Temperature, etc.
Process to create ohmic contacts by applying voltage across probe points.
Measures voltage vs. current to assess contact quality.
Records resistance (R) as a function of magnetic field (B).
Defines the magnetic field sweep type and segments for measurement.
Configures parameters like current, dwell time, and resolution for R vs. Field measurement.
Measures resistance (R) as a function of temperature.
Measures resistance (R) as a function of angle.
Steps to load, save, and start a measurement sequence.
How to open and view measurement results.
Accessing manual control for field and temperature.
Manually setting the magnetic field strength.
Manually setting the sample temperature.
Procedures for operating the MR insert with VSM temperature options.
Discusses sample dimensions and how pin placement affects measurements.
Identifies and addresses skew errors in MR curves due to misalignment.
Procedure to test for asymmetry in MR curves.
Steps to re-seat probe points to correct measurement skew.
Methods for post-processing data, like field averaging, to reduce errors.
Guidelines for achieving consistent R measurements.
Best practices for handling samples to ensure reproducible placement.
Advice on creating a guide for consistent sample placement.
Information on maintaining and replacing probe pins.
Detailed steps to take apart the MR insert probe.
Procedures for replacing internal components of the MR insert.
Guide to replacing the ceramic holder and pin guide.
Instructions for soldering probe pins to the printed circuit board.
Steps to put the MR insert probe back together.
How to reassemble the internal components of the MR insert.
Steps to attach the top cover to the MR insert body.