Table of Contents

Questions and Answers

Summary

General Information

Safety Precautions

Details essential safety precautions to minimize risk of fire or shock hazard.

Specifications

Lists performance specifications, ripple, programming speed, etc.

Input Power

Provides maximum input current and recommended wire size for AC input.

Regulation

Describes output voltage and current regulation under load changes.

Remote Programming

Explains capability for remote programming via external signals.

Over Temperature Protection

Explains thermostat-based protection and automatic restart.

Overvoltage Protection (for Outputs ≤ 300 VDC)

Describes OVP circuitry that shorts the output to protect the load.

Inspection and Installation

Visual Inspection

Guides on inspecting the unit for damage after unpacking.

Electrical Installation

Details AC input voltage connection and wire gauge requirements.

Electrical Inspection

Provides a step-by-step procedure for preliminary electrical testing.

Operating Instructions

Front Panel

Describes front panel controls and indicators with their functions.

Parallel Operation

Provides guidelines for connecting multiple supplies in parallel.

Parallel Operation - Master;Slave

Details configuration for parallel operation with a master/slave setup.

Series Operation

Explains how to connect power supplies in series for higher voltage.

Series Operation Master;Slave

Describes series operation where one supply controls others.

Theory of Operation

Overvoltage Protection

Details the overvoltage trip setpoint and latching mechanism.

Over Current Protection

Details the monitoring of current for peak current limiting.

Calibration and Troubleshooting

Calibration

Outlines calibration procedures and required equipment.

Voltage Channel and Voltmeter Calibration

Provides steps to calibrate the voltage channel and voltmeter.

Current Channel and Ammeter Calibration

Provides steps to calibrate the current channel and ammeter.

Troubleshooting

Lists common symptoms and probable causes for troubleshooting.

Lambda EMS 7.5-300 Specifications

General IconGeneral
Output Voltage7.5V
Output Current300A
Output Power2250W
Efficiency88%
Storage Temperature Range+85°C
Safety StandardsEN60950
ProtectionsOvervoltage, Overcurrent, Overtemperature