www.lamptron.com info@lamptron.com
Lamptron CM430 Instruction Manual
Thank you for choosing LAMPTRON CM430 controller.It
is optimized for air-cooled applications.
Limited Edition:Unque Colors except PWM Control,
Touch , Red-Blue Color and UV Color.
FEATURES:
PWM control
Colorful touch display
Red-Blue Color and UV Color version for your choice
Manual/Auto control
Compatible with PWM fans and stardard fans
Alarm temperature can be adjustable
Differences compared with CM430:
1)Touch Voice can be OFF
2) Adding the function of case temperature measurement
3)Wrong operation reminders
SPECIFICATION:
Dimension 148.5mm * 42.5mm * 63mm
Screen dimension 129mm * 32.5mm(wider screen)
Power output Up to 30 watts per channel
Control channels 4 Channels(1 PWM+3 Stardard Channel)
DC Input +12V(Standard” D” Connector)
DC Ouput 0 V - 12V DC
Compatible PWM and Standard Fans
Color Available UV,R&B
Alarm Alarm temperature can be adjusted
PWM Function PWM control
1
st
channel
INSTALLATION:
Installation location:
The CM430 is designed to fit in a 5.25” bay,please use the
included screws to install it within your pc case.(Phillips
screwdriver needed and not included.)
CONNECTIONS:
1.
POWER:to 4-Pin Molex Power Connector.
2. PWM: to PWM fans or stardard fans(Note:just 1st channel
offer PWM function)
3. OUT1
OUT3: to standard fans
4. TEMP0
TEMP3: to themal sensors.
OPERATION:
Power On/Off, long press for 3 seconds to turn it off
Start boost mode
Alarm switch
Backlight adjustment button
PWM output
⑹⑺⑻
Stardard Fan control output
Increase
Reduce
Automatic mode
Manual mode
Speed, voltage,
Percentage display
Unit display
Speed meter
Functional
area
Temperature
C/F
SETTING:
1. Manual/Auto control
Click to switch between auto and manual control,manual
mode was setuped as default.
2. Backlight brightness setting
Click to control brightness ranging 100% -- 50% -- 0%.
Power-on default is 100%. Backlight automaticly shutdown after 3
minutes in Auto Mode.
3. Alarm On/Off setting
Click for all the Alarm and Touch Voice on/off.
4. Start-boost setting
Click to set on/off Start-boost; the default is Off.
5. Functional area
Click to Select fan work mode between Quiet Mode/Fullpower
mode/ , , , .
for Fullpower which means 100% working ; for Quiet
Mode which means 40%working.
6. Operational settings for each channel
7. Speed, voltage, Percentage display
Click to switch in Speed/voltage/Percentage display.
8. Alarm setting
Long press over 3 seconds to set high or low temperature
for alarming.