PAGE 1
In the event that you need assistance for servicing your water lter, please rst contact the
professional contractor who installed the system.
Congratulations on purchasing your new Lancaster Water Filter. This unit is designed to give you
many years of trouble free service. For servicing and future inspection purposes, please le this
booklet with your important documents.
ELECTRONIC WATER FILTER WITH THE
X-FACTOR DIAMOND LINE CONTROL VALVE
INSTALLATION, OPERATING AND
SERVICE MANUAL
WATER FILTERS AND NEUTRALIZERS
ACID NEUTRALIZERS
7-LXDAN-1B
7-LXDAN-1.5B
7-LXDAN-2B
7-LXDAN-3B
IRON FILTER
7-LXIM-1B
7-LXIM-2B
7-LXIM-3B
AERATION-SULFUR &
IRON
7-LXCTAIR-1B
7-LXCTAIR-2B
7-LXCTAIR-3B
AERATION-IRON ONLY
7-LXIMAIR-1B
7-LXIMAIR-2B
7-LXIMAIR-3B
COLOR, TASTE, ODOR
7-LXCT-1B
7-LXCT-2B
7-LXCT-3B
SEDIMENT AND
TURBIDITY
7-LXST-1B
7-LXST-2B
7-LXST-3B
7-LXKATAIR-2B 7-LXKATAIR-3B 7-LXKATAIR-1B
AERATION-SULFUR, IRON, MANGANESE
7-LXKATAIRO3-2B 7-LXKATAIRO3-1B
OZONATION-SULFUR, IRON, MANGANESE, NUISANCE BACTERIA

Questions and Answers

  • K
    Kelly CunninghamAug 21, 2025
    How to fix a Lancaster Water Filtration System with no display on PC board?
    • N
      njonesAug 21, 2025
      If your Lancaster Water Filtration System's PC board has no display, here's what you can check: 1. Ensure the electric outlet has power; repair or try a working outlet. 2. Verify the control valve power adapter is plugged into the outlet and properly connected to the PC board. 3. Confirm the power supply delivers the correct voltage to the PC board. 4. If the issue persists, the power adapter or PC board may be defective and require replacement.
  • J
    johnsonashleyAug 23, 2025
    Why does my Lancaster Water Filtration System control valve backwash at the wrong time of day?
    • M
      Michael BrownAug 23, 2025
      If your Lancaster Water Filtration System's control valve backwashes at the wrong time, it could be due to several reasons: * A power outage may have occurred, requiring you to reset the time of day. * The time of day might not be set correctly; ensure it's properly configured. * The backwash time itself might be set incorrectly; reset it to the desired time. * The control valve might be set to immediate regeneration instead of delayed; check the programming and switch to DELAYED mode.
  • J
    Jill OsborneAug 25, 2025
    What to do if Lancaster 7-LXDAN-1.5B Water Filtration Systems PC Board does not display correct time of day?
    • A
      Alexandria WrightAug 25, 2025
      If the PC Board of your Lancaster Water Filtration System displays the wrong time, here are some potential causes and solutions: * The power adapter might be plugged into an outlet controlled by a light switch; use an uninterrupted outlet instead. * A breaker switch or GFI might have tripped; reset them. * There may have been a power outage; reset the time of day. If your PC board has a battery backup, the battery may be depleted. * The PC Board itself could be defective and need replacement.
  • A
    April RodriguezAug 26, 2025
    Why doesn't the display on my Lancaster Water Filtration System indicate water is flowing?
    • B
      Bradley ClarkAug 26, 2025
      If the display on your Lancaster Water Filtration System doesn't show water flowing, consider these possibilities: * The bypass valve might be in the bypass position; turn the handles to place it in the service position. * The meter might not be connected to the meter connection on the PC Board; connect it to the three-pin connection labeled 'METER'. * The meter turbine could be restricted or stalled; remove the meter and check for rotation or foreign material. * The meter wire might not be securely installed in the three-pin connector; verify the wires are securely in the connector labeled 'METER'. * The meter itself could be defective and require replacement. * The PC Board could be defective and require replacement.
  • K
    krystal90Aug 27, 2025
    Why is the time of day flashing on and off on my Lancaster Water Filtration System?
    • R
      rachelshieldsAug 27, 2025
      The time of day flashing on and off on your Lancaster Water Filtration System usually indicates a power outage. Reset the time of day.
  • J
    Jesse HernandezAug 31, 2025
    How to troubleshoot no display on my Lancaster Water Dispenser PC board?
    • C
      Carol AndersonAug 31, 2025
      If there is no display on the PC board of your Lancaster Water Dispenser, consider the following: 1. Check if there is power at the electrical outlet. Repair the outlet or use a working one if necessary. 2. Ensure the control valve power adapter is plugged into the outlet and that the power cord end is connected to the PC board connection. Plug the power adapter in or connect the power cord as needed. 3. Verify that the proper voltage is being delivered to the PC board. 4. If the power adapter is defective, replace it. 5. If the PC board is defective, replace it.
  • C
    Catherine VelazquezSep 1, 2025
    What to do if my Lancaster Water Dispenser control valve backwashes at the wrong time?
    • D
      Darius KeySep 1, 2025
      If the control valve on your Lancaster Water Dispenser backwashes at the wrong time, here are a few things to check: * If there was a power outage, reset the time of day. If the PC Board has a battery backup, the battery may be depleted. * Ensure the time of day is set correctly; if not, reset it. * Verify the backwash time is set correctly; if not, reset it. * Check if the control valve is set at immediate regeneration. If so, reset it to DELAYED for a delayed regeneration time. * Also, check if the control valve is set at (delayed + immediate). If so, reset it to DELAYED for a delayed regeneration time.
  • B
    Brittany CurtisSep 4, 2025
    Why does my Lancaster Water Dispenser PC board display the incorrect time?
    • J
      Jonathan RodgersSep 5, 2025
      If the PC board on your Lancaster Water Dispenser doesn't display the correct time of day, it could be due to: * The power adapter being plugged into an electrical outlet controlled by a light switch. Use an uninterrupted outlet instead. * A tripped breaker switch or GFI. Reset the breaker switch or GFI switch. * A power outage. Reset the time of day. If the PC board has a battery backup, the battery may be depleted. * A defective PC board. Replace the PC board.
  • J
    Joseph JacksonSep 12, 2025
    Why is my Lancaster Water Dispenser running water to drain?
    • L
      Luis YoungSep 12, 2025
      If your Lancaster Water Dispenser is constantly running water to the drain, here are some possible reasons: * A power outage occurred during backwash. Upon power being restored, the control will finish the remaining backwash time. Reset the time of day. * The seal/stack assembly is damaged. Replace the seal/stack assembly. * There is piston assembly failure. Replace the piston assembly. * The drive cap assembly is not tightened properly. Re-tighten the drive cap assembly.
  • W
    Willie WalkerSep 15, 2025
    What does error 104 mean on my Lancaster Water Dispenser?
    • K
      Kristen CoxSep 15, 2025
      Error 104 on your Lancaster Water Dispenser indicates that the control valve motor ran too long and timed out trying to reach the home position. This is often because: * The drive bracket is not snapped in properly, preventing the reduction gears and drive gear from interfacing. Snap the drive bracket in properly, then press the NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC Board for 5 seconds and then reconnect.

Lancaster 7-LXDAN-1.5B Specifications

General IconGeneral
Model Number7-LXDAN-1.5B
CategoryWater Filtration Systems
Operating Pressure20-100 PSI
Operating Temperature40-100°F
pH Range6.5-8.5
Filtration Capacity1.5 GPM