815 LX / UTILIZATION
CHAPTER 5 PROBLEMS 47
N°3 H
EATING EXCESS
.
F A U L T n ° 0 3
H E A T I N G E X C E S S
Heating Excess Definition
:
Is displayed if the basin temperature exceeds the programmed temperature
by 20°C.
Corrective Action
:
Verify that the incoming water temperature does not exceed the
programmed setpoint temperature.
CONTACT A MAINTENANCE TECHNICIAN.
N°4 H
EATING FAULT.
F A U L T n ° 0 4
H E A T I N G F A U L T
Heating Fault Definition
:
This message is displayed during one of the heating phases if the water
temperature has not increased after 8 minutes of heating duration.
Corrective Action
:
CONTACT A MAINTENANCE TECHNICIAN TO CHECK :
- the electrical connections,
- the condition of heating elements,
- the safety thermal cut-out with manual reset.
This message may be displayed during the heating phase of
PREWASH
1,
PREWASH
2,
WASH
, and
HOT DEMI
.
WATER RINSE
.