Details the 12-key keypad for voucher entry and function access.
Explains the LCD's role in displaying credit, entries, and meter status.
Describes the red LED indicating instantaneous power consumption.
Details the port for data transfer using an interrogation device.
Explains the yellow LED providing diagnostic status and fault indications.
Describes the green LED indicating communication status with the CIU.
Details the 12-key keypad for voucher entry and function access.
Explains the LCD's role in displaying credit, entries, and information.
Describes the red LED indicating instantaneous power consumption.
Explains the yellow LED indicating low credit levels.
Explains the meaning of pictograms and icons displayed on the LCD.
Illustrates common LCD displays for normal, low credit, and zero credit conditions.
Describes the use of smiley face icons for status indication.
Explains the low credit warning indicator functionality.
Details the icon indicating whether electricity is supplied or disconnected.
Describes the 4-segment wedge indicating remaining credit levels.
Explains the icon indicating the meter is in information mode.
Describes the icon shown when the meter operates in credit metering mode.
Explains the icon indicating power consumption display.
Provides an overview of the prepayment meter's features and functions.
Details what the LCD displays during normal meter operation.
Step-by-step guide for entering prepayment vouchers using the keypad.
Explains how the meter processes entered prepayment vouchers.
Describes the meter's response to incomplete voucher entries.
Outlines the sequences following a complete voucher entry.
Describes the display when a voucher is successfully accepted.
Details the display for STS key change voucher acceptance.
Explains display for valid vouchers causing credit overflow.
Describes the display for incorrect or rejected voucher entries.
Explains the display when a previously used voucher is entered.
Describes the display for expired STS vouchers.
Details the process of decrypting and processing various voucher formats.
Information on vouchers adhering to the Standard Transfer Specification (STS) format.
Describes the function of electricity credit vouchers.
Procedure for setting the first dispenser key for security.
Procedure for setting the second dispenser key for security.
Voucher to restore operation after a tamper condition.
Voucher used to configure the meter's power limit.
Voucher to set specific credit levels for the meter.
Voucher to zero remaining credit and open the load switch.
Voucher for performing diagnostic tests on the meter.
Voucher for initial meter installation and commissioning.
Meter-specific voucher for initial installation and commissioning.
Voucher used to decommission or remove the meter.
Voucher to set the meter into credit metering mode.
Voucher to set the meter back into prepayment metering mode.
Information on vouchers using the proprietary format with 16-digit numbers.
Voucher for transferring a variable quantity of credit to the meter.
Voucher for key changes, often including embedded credit.
Procedure for performing an initial key change.
Voucher to restore normal operation after a tamper event.
Voucher to set specific power limit levels for the meter.
Voucher to set credit levels affecting LCD indicators.
Voucher to clear credit and open the load switch.
Voucher to clear logged meter entries.
Voucher to initiate a load switch test without meter specificity.
Voucher for non-specific meter installation and commissioning.
Meter-specific voucher for installation and commissioning.
Meter-specific voucher for decommissioning.
Details on managing meter modes for installation and removal.
Option to configure meter display for total units versus remaining credit.
Explains the power limiting feature and its algorithm.
Describes how the load switch reconnects after trips or power loss.
Option to automatically disconnect the load switch during power failures.
Details the port for data extraction in case of meter electronics failure.
Overview of the CIU's role as a remote display and keypad.
Details the optional audible warning for low credit levels.
Describes the various tones produced by the CIU for token entries.
Instructions on physically connecting the CIU to the meter.
Describes the physical sealing and evidence of tampering.
Explains the mechanical switch that detects terminal cover removal.
Details the meter's capability to detect and flag reverse power flow.
Procedure for clearing a tamper condition and restoring normal operation.
Displays the unique meter identity number.
Shows combined instantaneous power consumption across all phases.
Stores and displays the meter's current remaining credit.
Displays the total energy (kWh) consumed since installation.
Displays consumption data for the current 24-hour period.
Displays consumption data for the previous 24-hour period.
Displays consumption data for the current 30-day period.
Displays consumption data for the previous 30-day period.
Indicates the credit level triggering low credit warnings.
Indicates the credit level for high credit status indicators.
Shows the power limit at which the load switch will open.
Displays instantaneous power consumption on Phase 1.
Displays instantaneous power consumption on Phase 2.
Displays instantaneous power consumption on Phase 3.
Indicates when low consumption prevents metering.
Displays missing digits of an STS meter number for identification.
Shows fixed meter states stored in EEPROM, indicating operational status.
Displays meter functions personalized at manufacture, not changeable.
Displays meter functions that can be changed via voucher.
Shows meter states during startup or normal operation.
Displays the meter's software version number.
Counts the number of power failures experienced by the meter.
Displays the date and time of the last credit voucher entry.
Shows the identifier of the last voucher entered into the meter.
Displays the value (in kWh) of the last credit voucher entered.
Refers to STS specifications for key revision and type details.
Refers to STS specifications for tariff index information.
Displays credit register with high resolution (0.01kWh).
Contains initial SGC, indicating if a key change has occurred.
Displays total units consumed with high resolution (0.01kWh).