5: Commands and Levels
SGX™ 5150 IoT Device Gateway Command Reference 98
flush stop character ena-
ble
Prevents the stop character from the Line from being forwarded to the network.
modem control disable
Does not watch the modem control pin to disconnect.
modem control enable
Watches the modem control pin and disconnects if it is not asserted.
no stop character
Removes the stop character.
no timeout
Disables disconnect after timeout feature for tunneling sessions.
show
Displays the current configuration.
show history
Displays the last 20 commands entered during the current CLI session.
stop character <control>
Sets the stop character. The character may be input as text, control, decimal, or hex. A
control character has the form <control>C. A decimal value character has the form \99. A
hex value character has the form 0xFF.
timeout <milliseconds>
Disconnects when no data has been received on the line (serial port) for the specified
length of time. <milliseconds> = timeout in milliseconds.
write
Stores the current configuration in permanent memory.
disconnect (tunnel-disconnect:2) level commands
clrscrn
Clears the screen.
exit
Returns to the tunnel level.
flush serial disable
Does not flush serial data upon closing a tunneling connection.
flush serial enable
Flushes serial data buffer when a tunneling connection is closed.
flush stop character dis-
able
Forwards the stop character from the Line to the network.
flush stop character ena-
ble
Prevents the stop character from the Line from being forwarded to the network.
modem control disable
Does not watch the modem control pin to disconnect.
modem control enable
Watches the modem control pin and disconnects if it is not asserted.
no stop character
Removes the stop character.
no timeout
Disables disconnect after timeout feature for tunneling sessions.
show
Displays the current configuration.
show history
Displays the last 20 commands entered during the current CLI session.
stop character <control>
Sets the stop character. The character may be input as text, control, decimal, or hex. A
control character has the form <control>C. A decimal value character has the form \99. A
hex value character has the form 0xFF.
timeout <milliseconds>
Disconnects when no data has been received on the line (serial port) for the specified
length of time. <milliseconds> = timeout in milliseconds.
write
Stores the current configuration in permanent memory.
disconnect (tunnel-disconnect:1) level commands
clrscrn
Clears the screen.
exit
Returns to the tunnel level.
flush serial disable
Does not flush serial data upon closing a tunneling connection.
flush serial enable
Flushes serial data buffer when a tunneling connection is closed.
flush stop character dis-
able
Forwards the stop character from the Line to the network.
flush stop character ena-
ble
Prevents the stop character from the Line from being forwarded to the network.
modem control disable
Does not watch the modem control pin to disconnect.
modem control enable
Watches the modem control pin and disconnects if it is not asserted.
no stop character
Removes the stop character.
no timeout
Disables disconnect after timeout feature for tunneling sessions.

Other manuals for Lantronix SGX 5150

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix SGX 5150 and is the answer not in the manual?

Lantronix SGX 5150 Specifications

General IconGeneral
CertificationFCC ICES-003:2012 RED 2014/53/EU, EMCD 2014/30/EU, EN 300 328 V1.9.1, EN 301 489-1 V1.9.2, EN301 489-17 V2.2.1, EN 301 893 V1.8.1, EN 62311: 2008 AS/NZS CISPR 22, AS/NZS 4268: A1: 2013, AS/NZS 2772.2VCCI EN 55022:2010, EN 55024:2010, EN 61000-3-2:A2 2009, EN 61000-3-3: 2008 UL 60950/CSA 22.2 No. 60950, IEC 60950 CE LVD 2014/35/EU
LED indicatorsYes
Power requirements9 - 30 VDC
Power over Ethernet (PoE)No
Power consumption (typical)1.9 W
Storage temperature (T-T)-40 - 85 °C
Operating temperature (T-T)-40 - 70 °C
Operating relative humidity (H-H)5 - 95 %
Security algorithms802.1x RADIUS, AES, EAP-FAST, EAP-PEAP, EAP-TLS, EAP-TTLS, FIPS 140-2, MSCHAPv2, TKIP, WPA, WPA2, WPA2-PSK, WPS
Authentication methodRADIUS
Ethernet LAN (RJ-45) ports1
Supported protocolsIPv4/IPv6, TCP, UDP, ICMP, ARP, Auto-IP, DNS, (S)FTP
Frequency band2.4 / 5 GHz
Cabling technology10/100BASE-T(X)
Networking standardsIEEE 802.11a, IEEE 802.11ac, IEEE 802.11b, IEEE 802.11d, IEEE 802.11g, IEEE 802.11h, IEEE 802.11i, IEEE 802.11n, IEEE 802.1x, IEEE 802.3, IEEE 802.3af, IEEE 802.3at, IEEE 802.3u
Ethernet LAN data rates10, 100 Mbit/s
Weight and Dimensions IconWeight and Dimensions
Weight350 g
Dimensions (WxDxH)110 x 89 x 26 mm