HYDRAULIC CONNECTIONS
Water supply
- Pipe section: minimum ø16 mm.
- Feed the appliance with warm water (not above 55°C) supplied at a pressure between 200
and 400 kPa (2/4 bar) during the rinsing phase. The pressure of supplied water must remain
within these values. In case pressure increases too much or becomes unstable, a pressure
reducer should be installed.
- Let some water run in the new pipes before installing the appliance.
- Before installation, check water hardness and install a water softener if hardness is above
15°F.
MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE
INSTALLATION, USE AND MAINTENANCE MANUAL
10
LS 4 models
Legend
A Water supply (Ø ¾” G)
S Gravity drain (Ø 35 mm)
P Power supply
A
S
P
A
S
P