Function Range Resolution
Accuracy
% of measured value (rdg)
+ least significant digits
AC voltage (Auto range)
Frequency (Auto range)
Accuracy: ± (1.0% rdg ±5 digits)
Frequency range: 40 Hz ... 1 kHz
Sensitivity: > 15 V RMS
Duty cycle
Accuracy: 5% … 95% ± (1,5% rdg ± 10 digits)
Frequency range: 40 Hz ... 1 kHz
Sensitivity: > 15 V RMS
DC voltage (Auto range)
500.00 mV 0.01 mV
± (1,0% rdg ± 8 digits)
5.0000 V 0.1 mV
50.000 V 1 mV
500.00 V 10 mV
1000.0 V 0.1 V ± (1,5% rdg ± 3 digits)
Resistance (Auto range)
500.00 Ω 0.01 Ω ± (1,0% rdg ± 9 digits)
5.0000 kΩ 0.1 Ω
± (1,0% rdg ± 5 digits)50.000 kΩ 1 Ω
500.00 kΩ 10 Ω
5.0000 MΩ 100 Ω ± (2,0% rdg ± 10 digits)
50.000 MΩ 1 kΩ ± (3,0% rdg ± 10 digits)
Capacitance (Auto range)
500.00 nF 10 pF ± (3,5% rdg ± 40 digits)
5000.0 nF 0.1 nF
± (5,0% rdg ± 10 digits)
50.000 µF 1 nF
500.00 µF 10 nF
5.000 mF 1 µF
Frequency (Auto range)
50.000 Hz 0.001 Hz
± (0,3% rdg ± 2 digits)
500.00 Hz 0.01 Hz
5.0000 kHz 0.1 Hz
50.000 kHz 1 Hz
500.00 kHz 10 Hz
5.0000 MHz 100 Hz
10.000 MHz 1 kHZ
Pulse width: 100 μs ... 100 ms
Frequency: 50 Hz ...100 kHz
Sensitivity: > 15 V RMS
Duty cycle
5% … 95% 0.1% ± (1,0% rdg ± 2 digits)
Pulse width: 100 μs ... 100 ms
Frequency: 50 Hz ...100 kHz
Sensitivity: > 15 V RMS
26
EN

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LaserLiner ClampMeter XP and is the answer not in the manual?

LaserLiner ClampMeter XP Specifications

General IconGeneral
BrandLaserLiner
ModelClampMeter XP
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals