Important notices
The laser points to the location that will be measured.
No objects may get into the laser‘s line of measurement.
The device compensates the measurement for different room
temperatures. Therefore allow the device a brief adaptation period
when changing locations with large temperature differences.
The device is only conditionally useable in outdoor areas and cannot
be used in strong sunlight.
The measurement results of outdoor measurements may be influenced
or falsified by rain, fog and snow.
In unfavourable conditions, e.g. with poorly reflecting surfaces, the
maximum deviation may be greater than 3mm.
Carpeting, upholstery or curtains will not reflect the laser optimally.
Measure to flat surfaces.
Measurements made through glass (window panes) can falsify
measurement results.
An energy-saving function switches the device off automatically.
Clean with a soft cloth. Water may not be allowed to penetrate
the housing.
Error codes:
Err101:
Err104:
Err152:
Err153:
Err154:
Err155:
Err156:
Err157:
Err160:
Replace the battery
Calculation error
Temperature is too high: > 40°C
Temperature is too low: < 0°C
Outside the measuring range
Received signal too weak
Received signal too strong
Incorrect measurement or background is too bright
The device is moving too much to measure.
3 sec
View stored valuesor
Memory function:
EN
2x1x 3x
3 sec1 sec
Min/max continuous measurement:
Device on Press for 3 seconds Stop
then release button
The LC display shows the max value, the min value and the current value.