ThermoCamera Connect
02
14
26
38
50
DE
EN
NL
DA
FR
ES
IT
PL
FI
PT
SV
NO
TR
RU
UK
CS
ET
RO
BG
EL
COLOUR TFT
Question and Answer IconNeed help?

Do you have a question about the LaserLiner ThermoCamera Connect and is the answer not in the manual?

Overview

The ThermoCamera Connect is a versatile thermal imaging device designed for non-contact surface temperature measurement and visual display of thermal patterns. It utilizes an integrated unchilled microbolometer to evaluate radiation in the infrared wavelength range, providing a visual image of temperatures surrounding an inspected object. The device translates temperature differences into a thermogram with a false-color display, making thermal patterns easily discernible.

Function / Application

The primary function of the ThermoCamera Connect is to visualize thermal patterns and enable non-contact measurement of surfaces. Its imaging technology captures temperature differences and displays them using color-coding in a thermogram. This capability makes it suitable for a wide range of applications, including:

  • Electrical Component Analysis: Locating overloads in electrical components to prevent failures.
  • Mechanical Component Inspection: Detecting overheating in mechanical parts, which can indicate friction or wear.
  • Building Diagnostics: Pinpointing and analyzing heating lines in walls and floors, identifying insulation issues, and detecting moisture.
  • HVAC Systems: Assessing refrigerant and air conditioning systems for efficiency and potential problems.
  • General Temperature Monitoring: Any application requiring visual representation of temperature distribution across a surface.

Usage Features

The ThermoCamera Connect is designed for user-friendly operation with a clear interface and intuitive controls.

General Safety Instructions:

  • Always use the device according to its intended purpose and within specified limits.
  • Keep the device and its accessories out of reach of children.
  • Avoid unauthorized modifications or changes, as these will invalidate approvals and safety specifications.
  • Protect the device from mechanical stress, extreme temperatures, moisture, and significant vibration.
  • Discontinue use if any function fails or the battery charge is low.
  • Only use genuine accessories to maintain warranty validity.
  • Battery charging progress can be checked by briefly pressing the ON/OFF button. A weak battery charge is indicated in red.
  • The battery can be charged while the device is in use.
  • Disconnect the power pack from the mains when the device is not in use.
  • Never use unapproved extension cables or accessories with the battery charger to avoid fire, electric shock, or injury.

Safety Instructions for Electromagnetic and RF Wireless Radiation:

  • Be aware of local operating restrictions in sensitive environments like hospitals, aircraft, petrol stations, or near people with pacemakers, as electronic devices can cause hazards or interference.
  • High voltages or strong electromagnetic alternating fields may affect measurement accuracy.
  • The device is equipped with a wireless interface and complies with electromagnetic compatibility and wireless radiation regulations (RED 2014/53/EU).
  • To comply with CE radiation exposure limits for uncontrolled environments, maintain a minimum distance of 20 cm from the body when using the device to avoid wireless radiation.

Device Components:

  1. 3.2" TFT Colour Display: Provides a clear visual interface for viewing thermal images and menu options.
  2. Hot Keys: Dedicated buttons for quick access to frequently used functions.
  3. Lens Cover: Protects the infrared camera lens when not in use.
  4. Camera: The digital camera component.
  5. Infrared Camera Lens: The optical component for capturing thermal data.
  6. Trigger (Capture): Button to capture images.
  7. Battery Compartment: Houses the Li-ion battery pack.
  8. Shaft: The handle of the device.

Control Buttons:

  • a (ON/OFF): Powers the device on or off.
  • b (Menu Navigation): Used for navigating through menu options.
  • c (Menu Navigation / Select Digital Image, Overlay Infrared / Digital Image and Infrared Image): Multi-functional button for menu navigation and selecting image display modes.
  • d (Open Main Menu / Exit Main Menu (Cancel) / Save Image): Accesses the main menu, exits menus, or saves captured images.
  • e (Control Menu (Confirmation) / Do Not Save Image): Confirms selections in control menus or discards images.
  • f (Control Menu (Cancel)): Cancels actions in control menus.
  • g (Menu Navigation / Select Digital Image, Overlay Infrared / Digital Image and Infrared Image): Similar to 'c', used for navigation and image mode selection.
  • h (Menu Navigation): General menu navigation.
  • i (Micro USB Interface): Used for charging the device.

Standard Measurement View:

The display shows key information during measurement:

  1. Temperature at Centre of Image: The temperature reading at the central measurement point.
  2. WLAN Active: Indicates if the WLAN connection is active.
  3. Set Emissivity Coefficient: Displays the current emissivity setting.
  4. Battery Charge Indicator: Shows the remaining battery life.
  5. Colour Palette: The selected color scheme for the thermogram.
  6. Time: Current time.
  7. Min. Temperature: The lowest temperature detected in the current view.
  8. Max. Temperature: The highest temperature detected in the current view.
  9. Temperature at Centre of Image: Redundant display of the central temperature.
  10. Max. Temperature: Redundant display of the maximum temperature.
  11. Thermography Image: The thermal image itself.
  12. Min. Temperature: Redundant display of the minimum temperature.

The main menu provides access to various settings and functions: 13. Open Media Gallery: View saved images. 14. Change Colour Palette: Select different color schemes for thermal images. 15. Set Emissivity Coefficient: Adjust the emissivity value for accurate measurements. 16. Settings: Access general device settings.

Within the settings menu, users can customize various aspects of the device: 17. Auto Shutdown: Configure the device to automatically switch off after a period of inactivity (e.g., 5 min, 20 min, or off). 18. Display Brightness: Adjust the screen brightness (Low, Medium, High). 19. Menu Language: Select the desired language for the menu (English, Deutsch, Français, Nederlands, Italiano, Español, Dansk, Suomalainen, Svenska). 20. Time Format: Choose between 24-hour or AM/PM format. 21. Time Settings: Set the current year, month, day, hour, minute, and second. 22. Spot (Measuring Point): Enable or disable additional measurement spots (Max: highest temperature, Min: lowest temperature). 23. WLAN Connection ON/OFF: Toggle the WLAN connection. 24. Image Correction: Adjust image settings. 25. Software Version: Display the current software version.

Charging the Li-ion Battery:

  • Plug the supplied USB cable into the charging socket (i) and connect it to a USB 2.0 power supply unit.
  • The device can be operated while charging.

Removing / Inserting Li-ion Battery Pack:

  • Open the battery compartment (7).
  • Remove or insert the Li-ion battery pack, ensuring correct polarity when inserting.

Image Modes:

The device offers five different image modes to suit various inspection needs:

  • IR Image (IR): Displays only the infrared thermal image.
  • Digital Image (Visible): Displays only the visual image captured by the digital camera.
  • Digital Image with IR Image Overlay (MIX), Level 1: Overlays the thermal image onto the digital image with a low level of transparency.
  • Digital Image with IR Image Overlay (MIX), Level 2: Overlays the thermal image onto the digital image with a medium level of transparency.
  • Digital Image with IR Image Overlay (MIX), Level 3: Overlays the thermal image onto the digital image with a high level of transparency.

Capture Image:

  • Use the "Trigger" button (6) to capture images of any measurement situation for subsequent documentation.
  • After capturing, the device will prompt whether to save the image.
  • All recorded images can be accessed in the media gallery.
  • Images can be deleted by pressing the MENU button. There are no safety prompts before deletion, so exercise caution.

WLAN Connection:

  • The ThermoCamera Connect can connect via WLAN to a terminal device (desktop PC or mobile phone) for data evaluation.
  • First, select the required WLAN SSID (MAC:MMMMMM) on the device.
  • The connection is then established on the terminal device.
  • Data is accessible via any modern browser at the IP address 192.168.230.1 Port 80.

Emissivity:

  • The emissivity coefficient (0.10 to 1.0) is crucial for accurate infrared measurements, as it depends on the specific material and surface.
  • Users can either set a custom emissivity value or select from predefined coefficients based on a material list (e.g., Matt (e=0.95), Semi-matt (e=0.85), Semi-gloss (e=0.60), Glossy (e=0.30), Individual).
  • Always check and adjust emissivity settings before each use to ensure accurate measurements.

Colour Ranges IR Image:

  • Users can choose from several standard color ranges to represent measured infrared temperatures.
  • The color palette adjusts the displayed temperatures within the current image section and maps them to the respective color space.
  • A bargraph indicates the minimum and maximum temperatures of the entire image, serving as a reference for temperature/color mapping.

Maintenance Features

Information on Maintenance and Care:

  • Clean all components with a damp cloth.
  • Do not use cleaning agents, scouring agents, or solvents.
  • Remove the battery pack before storing the device for longer periods.
  • Store the device in a clean and dry place.
  • Avoid touching the lens to prevent damage or smudges.

Calibration:

  • The meter requires regular calibration and testing to ensure accurate measurement results.
  • It is recommended to carry out calibration once a year.

EU Directives and Disposal:

  • The device complies with all necessary standards for the free movement of goods within the EU.
  • As an electric device, it must be collected separately for disposal according to the European Directive on waste electrical and electronic equipment.
  • Further safety and supplementary notices are available online.

LaserLiner ThermoCamera Connect Specifications

General IconGeneral
TypeThermal imaging camera
IR resolution160 x 120 pixels
Image frequency9 Hz
FocusFixed focus
Image storage formatJPEG
Operating time4 hours
Protection classIP54
Accuracy±2°C or ±2% of reading
EmissivityAdjustable from 0.1 to 1.0
InterfaceUSB
Power supplyRechargeable Li-ion battery
Spectral range8 - 14 µm
ConnectivityBluetooth
ApplicationBuilding inspection, electrical inspection, mechanical inspection
Temperature range-20°C ... 350°C