AF-3500
All-in-One EMF Meter
1. Quick Measurement Mode Operation:
Press the middle button
(as shown in the figure)
to turn on the meter
The startup screen appears
A
ccess the measurement
mode:
Electric field
Press and hold the middle
off the meter
button for 3 seconds to turn
2. Data Hold:
In the measurement mode,
press the left button
All measurement readings
and functions are locked
In the Data Hold mode,
press the left button
Return to the measurement
mode
All-in-One EMF Meter
AF-3500
All-in-One EMF Meter
AF-3500
All-in-One EMF Meter
AF-3500
All-in-One EMF Meter
AF-3500
All-in-One EMF Meter
AF-3500
All-in-One EMF Meter
AF-3500
All-in-One EMF Meter
AF-3500
All-in-One EMF Meter
AF-3500
Question and Answer IconNeed help?

Do you have a question about the LATNEX AF-3500 and is the answer not in the manual?

LATNEX AF-3500 Specifications

General IconGeneral
Display TypeLCD
Power Supply9V Battery
TypeAnemometer
Data HoldYes
Air Temperature Range0 to 45 °C
Air Velocity Accuracy± 3% + 0.1 m/s
Unitsm/s, km/h, ft/min, mph, knots, °C, °F
Measurement TypeAir velocity and temperature
Resolution0.1 m/s for air velocity, 0.1 °C for temperature

Summary

Quick Measurement Mode Operation

Turn On Meter

Press the middle button to turn on the EMF meter.

Startup Screen Display

The device displays the startup screen upon activation.

Access Measurement Mode

Enter the measurement mode, specifically for Electric Field.

Turn Off Meter

Press and hold the middle button for 3 seconds to power off the device.

Data Hold Functionality

Activate Data Hold

In measurement mode, press the left button to activate data hold.

Data Locked State

All measurement readings and functions are locked when data hold is active.

Return from Data Hold

In the Data Hold mode, press the left button to return to normal measurement.

Brightness and Field Functions

Brightness Circulation

Cycle through brightness levels: Low, Middle, High, and back to Low.

Field Measurement Types

Indicates functions for Electro Magnetic Field, Electric Field, and RF Electric Field.

Key Selection

Each independent key serves as a selection key for functions.

Menu Settings Navigation

Enter Main Menu

From measurement mode, press the middle button to access the main menu.

Navigate Menu Options

Use the right button 'Select' to move cursor and left button 'Enter' to confirm.

Cancel and Return

Press 'Menu' to return to the previous measurement mode if not proceeding.

Step 3: Configuration Options

Configure Magnetic Unit

Select between Gauss/mG or Tesla/µT for magnetic field measurement units.

Configure RF Strength Unit

Choose RF strength units: uW/m², mW/m², uW/cm², mV/m~V/m, mA/m, or dBm.

Configure Language

Select the display language from available options like English, Chinese, Japanese, Spanish.

Configure Power Off Timer

Set the auto power-off timer for 1, 5, 10, 15, or 30 minutes.

Configure Sound Setting

Enable or disable the device's sound feedback.

View Information

Access software version and other device information.