P a g e | 8
Specifications (Electric Ovens)/ Spécifications /
Especificaciones
Model /
Modèle /
Modele
H x W x D*
Clearance to Combustibles / Distance
aux combustibles / Distancia hasta
Combustibles
Weight / Poids / Peso
Class
/
Classe
/
Clase
Actual /
Réel / Real
Crated /
Crated /
Crated
LRO-1__
105 x 55 x 88"
[2654x1397x2235mm]
Sides 0, Back 0 /
Flanc 0, Derrière 0 /
Costado 0, Parte Posterior 0
2500 lb
[1135 kg]
3089 lb
[1315 kg]
77.5
LRO-2__
105 x 72 x 108"
[2654x1829x2743mm]
3380 lb
[1530 kg]
4380 lb
[1990 kg]
Electric Requirements / ExigenceÉlectriques / Requisitos Eléctricos
Model /
Modèle /
Modele
Voltage / Tension / Voltaje
kW
Min Circuit
Amps /
Circuit Min /
Circuito Mín
Max Breaker Amps
/ Disjoncteur de Max
/ Interruptor de Máx
LRO-1E5 208
208 VAC, 3ph, 60 Hz
41.5
145
175
LRO-1E5 240
240 VAC, 3ph, 60 Hz
41.5
125
150
LRO-1E5 480
480 VAC, 3ph, 60 Hz
40
85
105
LRO-2E5 208
208 VAC, 3ph, 60 Hz
51.6
180
200
LRO-2E5 240
240 VAC, 3ph, 60 Hz
55
165
200
LRO-2E5 480
480 VAC, 3ph, 60 Hz
55
85
100
LRO-E5 480
120V,1ph,60Hz (480V, U.S. only)
.42
15
20
Venting / Ventilation / Ventilación
Water / Eau / Agua
Model
CFM M3/Min ǂ
Pressure Drop
Eyebrow
Hood Type
Input Pressure / Pression
d'Entrée / Presión de Entrada
LRO-1__
530 15
1” wc
[250 Pa]
Type II or
Type I as
required.ǂǂ
40 psi [275 kPa] Min;
100 psi [700 kPa] Max
LRO-2__
800 23
Water Condition / Eau Condition / Agua Conditción
Alkalinity < 22 ppm
Magnesium < 0.65 ppm
Aluminum < 17 ppm
pH = 8.5
Calcium < 3.3 ppm
Sodium < 8.5 ppm
Free Chlorine Radical < 0.6 ppm
Total Hardness < 11.9 ppm
*
Clearance, tilt up / Dégagement d'incliner / Espacio libre para inclinara = 112" [2845mm]
**
Non-combustible floors supported by non-combustible structure / Planchers combustibles non pris en
charge par la structure combustible non / Pisos no combustibles soportados por la estructura no
combustible
ǂ
External roof-top fan required / Externe sur le toit ventilateur requis / Externa en la azotea requiere ventilador
ǂǂ
Per local Codes / Par codes locaux / Por códigos locales