INSTRUCTIONS GUIDE AND USER MANUAL WALL MOUNT HOODS.
IMPORTANT:
Read and save these instructions.
NOTICE:
Installer: Leave this guide with the homeowner
Homeowner: Keep this guide for future reference

Questions and Answers

  • R
    ramirezheatherJul 31, 2025
    Why is my Le Cappe WALL MOUNT HOODS Ventilation Hood not venting out properly?
    • T
      teresamaloneAug 1, 2025
      Several factors can affect the venting performance of your Le Cappe Ventilation Hood. Ensure the distance between the stove top and the hood's bottom is between 28” and 31”. Reduce the number of elbows and the length of duct work. Verify that all joints are properly connected, sealed, and taped. For heavy cooking, make sure the power is set to high speed.
  • M
    Melissa WebbAug 6, 2025
    What to do if my Le Cappe WALL MOUNT HOODS Ventilation Hood blower or fan seems weak?
    • M
      Melissa CastilloAug 6, 2025
      If the blower or fan on your Le Cappe Ventilation Hood seems weak, check the following: ensure the duct size used is at least 6” or 3-1/4 x 10” as the range hood WILL NOT function efficiently with insufficient duct size. Also, inspect the duct for clogs and verify that the damper unit (half-circular flapper) is installed correctly and opening properly. A tight mesh on a side wall cap unit might also restrict airflow.
  • M
    Michelle DavisAug 12, 2025
    What to do if my Le Cappe WALL MOUNT HOODS Ventilation Hood or halogen light does not operate after installation?
    • K
      kimberly27Aug 13, 2025
      If your Le Cappe Ventilation Hood or halogen light isn't working after installation: * Check if the hood is plugged in. * Ensure all power is turned ON. * Check the fuses and ensure they are not blown. * Verify all electrical wiring is properly connected. If the light is the issue, swap out the light assembly with working ones to see if the problem is defective bulbs.
  • S
    Samantha RobertsAug 18, 2025
    What to do if my Le Cappe WALL MOUNT HOODS lights work but the blower is not spinning, is stuck, or is rattling?
    • A
      Alex RiggsAug 18, 2025
      If the lights on your Le Cappe Ventilation Hood work, but the blower isn't spinning, is stuck, or rattling, the blower might be jammed or scraping the bottom due to shipping damage. Please contact us immediately.
  • U
    upayneAug 25, 2025
    Why does my Le Cappe WALL MOUNT HOODS Ventilation Hood vibrate when the blower is on?
    • W
      wallacelaurenAug 25, 2025
      If your Le Cappe Ventilation Hood vibrates when the blower is on, it might not be properly secured to the ceiling or wall. Check with your installer to ensure it is correctly mounted.

Summary

Le Cappe Wall Mount Hoods Manual

Important Safety Notice

Fire, Electric Shock, and Injury Prevention

Safety guidelines for preventing common hazards during operation.

Grease Fire Safety and Prevention

Measures to reduce the risk of stove top grease fires.

Advanced Safety Instructions

Grease Fire Response and Gas Leak Procedures

Actions to take during grease fires and gas leaks.

Understanding Safety Warnings

Explanation of the warning symbol and manufacturer liability.

Included Parts List

Venting and Mounting Requirements

Venting System Specifications

Details on duct size, materials, and termination for efficient airflow.

Height and Clearance Recommendations

Optimal mounting heights above the cooking surface.

Duct Run Calculation and Guidelines

Duct Size and Installation Rules

Minimum duct sizes and best practices for duct routing.

Calculating Total Duct Length

Method for determining maximum allowed duct run length.

Venting Methods Explained

Exhaust Venting Options

Vertical roof and horizontal wall venting procedures.

Recirculating Hood Conversion

Guide to converting the hood for air recirculation using filters.

Installation Preparations and Electrical

Charcoal Filter Installation Steps

Instructions for installing the charcoal filter for purifying air.

Electrical Connection Requirements

Specifications for safe and compliant electrical hookup.

Pre-Installation Steps

Range Hood Installation

Mounting and Securing the Hood

Procedures for attaching the hood to the wall.

Technical Specifications Summary

Key technical data like voltage, power, and airflow.

Control Panel: Grecia, Paris, Venice Pro

Button Functions and Indicators

Detailed explanation of each button and its function.

Control Panel: Moon & Viena

Button Functions and Indicators

Detailed explanation of each button and its function.

Control Panel: Messina & Athenas

Button Functions and Indicators

Detailed explanation of each button and its function.

Troubleshooting Common Issues

Use and Care Information

Detailed Specifications

Exterior Surface Cleaning

Guidelines for cleaning stainless steel surfaces without damage.

Cleaning Filters and Light Bulbs

Le Cappe One Year Limited Warranty

Le Cappe WALL MOUNT HOODS Specifications

General IconGeneral
MaterialStainless Steel
LightingLED
TypeWall Mount
Width30 inches
Number of Fan Speeds3
Noise Level65 dB
Vent TypeDucted