Thank you for purchasing this Le Veil product. Please read this
manual in its enrety to fully enjoy the benets and features
of this product. Please keep this manual for future reference.
Note: A clear lm is applied to the top screen face that can
be remove prior to using this product. Locate the clear tab
and simply peel to remove
Note: A clear lm is applied to the top screen face that can be remove
prior to using this product. Locate the clear tab and simply peel to remove.
Low water alarm indicator
Maintains up to 55 CB-FT humidors
Up to 110 CB-FT w/sub. tank (not included)
Two Powerful and quiet fans
Back-lit liquid crystal display
1. Humidity sensor
2. Flat power cable
3. Power port for
support slave unit
4. Air out venlaon
5. Air in venlaon
6. Water sensor
7. Power light
8. 12V power port
9. Control buons
10. Reset memory
buon
11. Support Leg
12. MP, XS, AP ports are
for future features
13. Bluetooth Adapter
Port
4
5
10
11
6
1
2
9
8
7
3
12
Humidity
Temperature
°C , °F
3Days Avrg
Max, Min
Current humidity in humidor
Current temperature in humidor
Celsius or Fahrenheit temperature
3 day average humidity in humidor
maximum or minimum humidity
Humidier Water Level
13
Humidier Instrucons
iCigar Pro DCH-67
We Care About Quality in Cigars
Question and Answer IconNeed help?

Do you have a question about the Le Veil iCigar Pro DCH-67 and is the answer not in the manual?

Summary

Product Introduction and Overview

Component Identification

Identifies all physical components of the iCigar Pro humidifier unit.

Connection Instructions

Flat Cable Connection Procedure

Step-by-step guide for connecting the main controller to the water tank using the flat cable.

Water Tank Setup and Operation

Initial Setup and Operations

Guides on filling the water tank, setting humidity levels, and basic operational controls.

Hygrometer Calibration and Safety

Recalibrating the Hygrometer

Instructions on how to adjust the hygrometer to match external readings.

Safety Warnings and Precautions

Important safety advice regarding water, electricity, and maintenance.

Overview

The iCigar Pro DCH-67 is a humidifier designed for cigar humidors, emphasizing quality and precise humidity control. It is engineered in the USA and manufactured in China, with patent rights issued and/or pending.

Function Description:

The primary function of the iCigar Pro DCH-67 is to maintain optimal humidity levels within cigar humidors. It achieves this through a combination of powerful fans, a water tank with a dry gel medium, and a highly accurate capacitive humidity sensor. The device actively monitors both humidity and temperature within the humidor and adjusts its operation to reach a user-defined target humidity. It can maintain up to 55 cubic feet (CB-FT) humidors on its own and up to 110 CB-FT when used with a sub-tank (not included).

Important Technical Specifications:

  • Humidity Sensor: Capacitive humidity sensor, similar to those used in commercial laboratories, offering superior accuracy compared to resistive sensors.
  • Humidifier Accuracy: +/- 1%
  • Humidity Range: 40%-90%
  • Wall Outlet Power: 100-240V AC, 12V DC
  • Size: 9"L x 4 3/4"W x 4 1/2"H
  • Fans: Two powerful and quiet fans for efficient air circulation.
  • Display: Back-lit liquid crystal display (LCD) showing current humidity, current temperature, 3-day average humidity, maximum/minimum humidity, and RH setting.
  • Water Level Indicator: Displays a water drop icon and beeps when water level is low.
  • Connectivity: Bluetooth Adapter Port (13), MP, XS, AP ports for future features (12).
  • Power Ports: 12V power port (8) and power port for support slave unit (3).

Usage Features:

  • Easy Setup: Involves pouring dry gel into the water tank, adding distilled or carbon filtered drinking water up to the water line, and allowing 20 minutes for gel absorption.
  • User-Friendly Interface: Features 'MODE', 'UP', and 'DOWN' buttons for setting target humidity, switching between Celsius and Fahrenheit, and displaying Max/Min humidity.
  • Target Humidity Setting: Users can press and hold the 'MODE' button for 3 seconds until the RH setting numbers flash, then use 'UP' and 'DOWN' buttons to adjust the desired humidity.
  • Temperature Display: Quickly pressing 'MODE' switches between °C and °F.
  • Max/Min Humidity Display: Pressing 'UP' or 'DOWN' displays the maximum and minimum humidity recorded.
  • Low Water Alarm: The LCD displays a water drop icon and beeps for 30 seconds when the water level is low. Any button press can turn off the alarm early.
  • Flat Cable Connection: A crucial connection between the Main Controller and Water Tank, requiring careful handling. Instructions are provided for connecting the flat cable to avoid damage, ensuring the blue side faces up and is centered when plugging into the cable lock.
  • Support Leg: Included for device stability (11).

Maintenance Features:

  • Gel Replacement: The dry gel in the water tank should be replaced yearly.
  • Water Refill: Use only distilled or carbon filtered drinking water to fill the tank to the water line. Overfilling can cause ventilation issues and short circuits.
  • Water Type Caution: Do not use tap water as it can damage the humidifier, humidors, and cigars. If using without gel, carbonated filtered drinking water is recommended over distilled water, as distilled water is too pure for the water sensor to detect.
  • Cleaning: If lime buildup is observed on the two water sensor poles, clean them with de-lime solution or vinegar. Care must be taken to prevent liquid from entering the humidifier.
  • Recalibration: The hygrometer can be recalibrated to match another capacitive humidity sensor. This involves holding the 'MODE' button and using 'UP' and 'DOWN' buttons to adjust the displayed humidity on the upper left side of the humidifier.
  • Reset Memory: A dedicated button (10) is available to reset memory.
  • Power Safety: Ensure the power plug is dry before plugging it into any power outlet and avoid having water near electrical connections.
  • Ventilation: The device includes air out (4) and air in (5) ventilation points, which should not be obstructed.