Connect the positive and negative poles of the battery with the positive and
negative poles of DC terminals separately. Do not confuse them, otherwise the
battery and generating set will burn out.
Do not connect the positive pole of the battery with its negative pole, otherwise
the battery damage will result.
Do not connect the positive pole of the DC terminal with its negative pole,
otherwise the generating set damage will result.
When a large capacity battery is charged, excessive current flows, the fuse
for the direct current will burn out.
Do not run the generating set while it is still connected with the battery.
Do not use DC 12V and AC at the same time.
CAUTION
Battery exhausts explosive gas. Keep sparks, flames, and cigarettes away from
the battery. To prevent from creating a spark near the battery, always connect
the charging cables to the battery first and only then to the generating set.
When disconnecting, you should disconnect the cables at the generating set
first.
Charge the battery at a well-ventilated place.
Before charging, remove the cap from each cell of the battery.
Stop charging if the electrolyte temperature exceed 45
℃
.