1. Operate the engine for about 3 minutes
and then stop.
2. Stop the engine. Drain the engine oil while
the engine is still warm and fill fresh oil.
3. Remove the screw plug on the cylinder head cover and refill 2cc engine oil, then
put the plug in place.
4 Recoil starting:
Push the decompression lever down(Non-compression position) and hold it
while you pull the recoil starter
23times.(Do not start the engine.)
Electric starting:
Turn the engine 2
3 seconds with the decompression lever set at the
non-compression position, and the starting key at the START
position.(Do not start the engine.)
5 Pull the decompression lever up. Pull the recoil starter slowly. Stop when you
feel resistance.( at this position, both intake/exhaust values are closed to prevent
the engine from the rust.)
6 Wipe off the oil and dirt from the engine and store in a dry place.
WARNING
Indication that the installation and major repair work shall be carried out only by
specifically trained personnel.