98
SETTINGS MENU
Adjust the settings for the M3i+ unit in the mobile app or online, in order to change
the settings, the device must be online. Below are system and test settings that you
can change if you wish. Factory default settings have been underlined.
General
Startup mode Indicates the start mode of the device
after it has been without power.
Home/
Away/
Last
Sound alert Indicates situations when the device
sounds an alarm.
Disabled/
Alarm/
Always
Silent time Indicates when the device is silent.
23:00–07:00
Sleep length The pre-set default time frame of the Pause mode.
1–24 hours
(3)
Time zone Time zone settings.
WET/CET/EET
Close valve in away mode The valve is closed when the unit is put into
Away mode.
Yes/No
Flow test (FT)
Enabled Enables or disables the flow test.
Yes/No
FT duration Away The Away mode allows the magnetic valve to
close. It activates the alarm after the water has
flown longer than the set time of flow.
1–999 s
(1)
FT duration Home Indicates the time that the flow of water is allowed
in Home mode before the flow alarm sounds. The
Home mode allows the magnetic valve to close if
the water flow continues after the set time.
1–240 min
(20)
FT alarm delay Indicates the additional time that the flow
of water is allowed in Home mode before
the valve closes.
0–240 min
(5)
Volume test (VT)
Max flow rate Indicates how much flow is allowed before
Volume Test Warning is given.
l/min
Daily volume Indicates the maximum allowed volume of
water that can be tapped per day before the
Volume Test warning is given.
l/day
Hourly volume Indicates the maximum allowed volume of
water that can be tapped per hour before the
Volume Test warning is given.
l/h
Tightness test (TT)
Enabled Enables or disables the tightness test.
Yes/No
Sensitivity High sensitivity reacts at lower pressure drops.
Should be adjusted to the size of the property.
Low/
Medium/
High
TT alarm delay When the tightness test alarm sounds, you can
set an additional time that indicates how long the
alarm is allowed to sound before the valve closes.
0–7 days
(1)
Pressure test duration Specifies how long a pressure test should last.
1–60 min
(20)
Pressure tests/day Number of pressure tests per day.
1–12
(1)
Pressure tests before
action
Specifies the number of consecutive pressure test
periods that may fail before a warning occurs.
1–4
(1)
Input handling
AUX1 in Indicates whether you prefer to switch
between the Home mode and the Away mode
with a separate button or with the burglar
alarm. In other cases the input can be set in a
way that the warning or alarm shows on an ex-
ternal device, i.e. Moisture sensor, thermostat
or pressure sensor. If it is set on Deactivated,
no activity will be registered through this input.
Disabled/
Home/
Away/
Warning/
Alarm
AUX1 active Indicates whether the input will be
activated when it is high or low.
High/Low
AUX2 in Indicates the operation of the AUX2 connection.
See previous description of AUX1.
Disabled/
Ho me/Awa y/
Warning/
Alarm
AUX2 active Indicates whether the input will be activated
when it is high or low.
High/Low
Output handling
AUX out active Specifies whether the AUX output should close
or open when activated. If ”Off is selected,
the output is not activated at events.
Disabled/
Open/
Closed
AUX event trigger Specifies whether the output should be
activated when the unit is in the Away state
or when it is in Home mode. Alternatively,
it can be chosen that it should instead be
activated in the event of warnings or in
the event of an alarm.
Home/
Away/
Warning/
Alarm
Freeze guard
Alarm level Type of alarm given when the alarm limit
is reached.
Disabled/
Warning/
Alarm
Alarm limit Alarms if the temperature drops below this
limit. Resets when the temperature rises
2 degrees.
1-25
(3)