1110
RESTART
Restart the unit by disconnecting power for a short amount of time.
FACTORY SETTINGS
Restore the control unit to factory settings by turning the power off and keeping both
the Mode button and Clear button pressed while you reconnect the power source.
MAINTENANCE
Perform the following maintenance once per year:
9 Check that Flow indicator is flashing when water is flowing.
9 Check the magnetic valve regularly. Set the system on Away mode, let in water
and check that the system shuts the water supply off.
TECHNICAL DETAILS
LEAKOMATIC M3i+
Control unit
Power source 24VDC
Measures 175(B) x 130(H) x 100(D) mm
WiFi IEEE 802.11 b/g/n
Open/WEP/WPA/WPA2
DHCP
Inputs AUX1 & AUX2 in
Outputs AUX out
(200 VAC/VDC, 500 mA)
Remote control Web, App (iOS & Android)
Valve unit
Valve thread ¾” – DN20
Pressure drop 0,30 bar
Max operating pressure 10 bar
Max flow 5,8 m
3
/h
Operational temperature +0 .. +90 °C (frost-free)
Valve position during
an electrical blackout
NO – Normally Open