8
9.3 Command Explain
9.3.1 Z-Wave Plus Info Command Report
6(ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_SLEEPING_REPORTING)
0 (ZWAVEPLUS_INFO_REPORT_NODE_TYPE_ZWAVEPLUS_NODE)
0x0C06 (ICON_TYPE_SPECIFIC_SENSOR_NOTIFICATION_ACCESS_CONTROL)
0x0C06 (ICON_TYPE_SPECIFIC_SENSOR_NOTIFICATION_ACCESS_CONTROL)
9.3.2 Association Command
Door/Window Sensor supports only one association group.
1. Notification Report.
Sensor will send Notification Report when the
sensor body and magnet removed or
combined.
2. Battery Report.
Sensor will send Battery Report when the
battery level is low and the battery report’s
value is 0xFF.
9.3.3 Association Group Info Command
A) Association Group Name Command Report
The ASSIC of Lifeline: 4C 69 66 65 6C 69 6E 65
B) Association Group Info Command Report
General: Lifeline, Profile MSB=0x00,Profile LSB=0x01
C) Association Group Command List Command Report
COMMAND_CLASS_NOTIFICATION(0x71)
NOTIFICATION_REPORT(0x05)
COMMAND_CLASS_BATTERY(0x80)
COMMAND_CLASS_DEVICE_RESET_LOCA
LLY(0x5A)
DEVICE_RESET_LOCALLY_NOTIFICATION
(0x01)