Aperio AT2 DX
MAN-0351, Revision A | 29 July 2019
User’s Guide

Table of Contents

Questions and Answers

  • M
    marvintorresAug 12, 2025
    What to do if having trouble scanning a particular slide with Leica BIOSYSTEMS Laboratory Equipment?
    • W
      wilsonteresaAug 12, 2025
      If you're having trouble scanning a particular slide, consider these points: * Is the slide tissue extremely thick or thin? * Is the slide extremely dark or faint? If so, use a parameter set such as faint. * Is the label large or located inside the area of interest? Remove the label or adjust the area of interest. * Are there pen marks on the coverslip? Remove the marks or perform a manual scan. * Is there dust or debris on the coverslip or bottom surface? Clean the slide. * Are there bubbles under the coverslip? Perform a manual scan. * Is there excess adhesive around edges of the coverslip? Clean or perform a manual scan.
  • L
    luisjordanAug 15, 2025
    How to fix Leica BIOSYSTEMS Laboratory Equipment scanner that fails to start up?
    • A
      Amanda JacksonAug 15, 2025
      If your scanner fails to start up, check the following: * Verify that the power switch at the back of the unit is on. * Ensure all scanner doors are closed, including the AutoLoader carousel door, as the scanner cannot start unless all doors are shut. * Click the Aperio Service Manager icon in the Windows task bar and check that the entry for the Controller has a green dot and says 'Stop Controller Service.' If it has a red dot and says 'Start Controller Service,' click the entry to restart it.
  • E
    Elaine BeckerAug 19, 2025
    Why is the entire image out of focus on my Leica BIOSYSTEMS Laboratory Equipment?
    • M
      Michael MartinezAug 19, 2025
      If the entire image is out of focus, verify that the slide is being held flat and not moving in the tray during scanning; tape down the slide if necessary. Also, optic surfaces (such as the objective) may contain finger prints.
  • M
    Miss Lauren WalkerAug 23, 2025
    What to do if autofocus did not detect at least four focus points using Leica BIOSYSTEMS Laboratory Equipment?
    • M
      Michael CarterAug 23, 2025
      If the autofocus did not detect at least four focus points, it may be because the tissue is too faint to scan; use the faint parameter set. You can also try performing a new presnap.
  • S
    smithchadAug 27, 2025
    Why are individual stripes of the image poorly focused on my Leica BIOSYSTEMS Laboratory Equipment?
    • R
      Richard AndersonAug 27, 2025
      If individual stripes of the image are poorly focused while neighboring stripes are perfect, this may indicate that the slide is moving during scanning. Verify that the slide tray is clean and the slide is sitting flat and not rocking.
  • J
    joyce17Sep 3, 2025
    How to prevent Tissue Finder from including non-tissue area in Leica BIOSYSTEMS Laboratory Equipment scan?
    • H
      Hannah RichardsSep 3, 2025
      To prevent the Tissue Finder from including a non-tissue area in the scan area of interest during the scan, perform a new presnap with a very clean, blank slide and repeat the manual load.
  • A
    Angelica LittleSep 7, 2025
    What to do if Leica BIOSYSTEMS Laboratory Equipment scanner cannot create a calibration image?
    • B
      Bianca ReyesSep 7, 2025
      If you receive an error message stating that the scanner cannot create a calibration image, set the line camera gains.
  • J
    James SmithDec 1, 2025
    What does it mean if Leica BIOSYSTEMS Laboratory Equipment displays 'bulb may be unusable'?
    • R
      richardsonbenjaminDec 1, 2025
      If the calibration image is displayed but the error message 'bulb may be unusable' appears, consider the following: * If the calibration image is clear but too dark or too bright, set the line camera gains. * If the calibration image contains considerable tissue, while looking at the video monitor display, click on a clear glass area without tissue and verify that location is clear. Then move the blue diamond (calibration point) to that clear area. * If the calibration image contains coverslip or other defects, try the parameter set coverslip to help the scanner ignore edges or defects. * If the calibration image is very uneven, verify the slide is sitting flat and repeat with another slide. An uneven calibration may also indicate optical misalignment due to mishandling which requ...

Summary

Introduction

Intended Use

Describes the system's purpose for in vitro diagnostic use with FFPE tissue.

Symbols and Warnings

Explains symbols used to alert users to potential dangers during scanner operation.

Compliance Specifications

Details the standards and regulations the device conforms to.

Startup and Shutdown

System Startup

Step-by-step instructions for powering on and initializing the Aperio AT2 DX scanner.

System Shutdown

Procedure for safely powering down the Aperio AT2 DX scanner and associated systems.

Calibration and Verification

Information on factory calibration and recommended annual maintenance.

Preparing for Scanning

Slide Preparation Tips

Guidance on preparing slides to ensure optimal scan quality and performance.

Coverslips and Label Issues

Details on coverslip application and proper slide labeling to prevent scanner jams.

Scanning Slides

Scanner Controls and Overview

Identifies key controls and indicators on the Aperio AT2 DX scanner unit.

Scanning Parameters and Settings

Explains preselected parameters and how to start the scanning console.

Barcode Requirement

Details the importance of barcodes for quality control and slide identification.

AutoLoader Operations

Instructions for using the AutoLoader for automated, multi-slide scanning.

Console Interface Basics

Introduces the rack view, batch view, and fundamental console concepts.

Console Workflow Tools

Quick reference for console icons and viewing scan status.

Scanning Modes

Covers batch scanning, fine-tuning, manual scanning, and scan batch tasks.

Advanced Scanning Techniques

Details on snapshots, focus points, calibration, and z-stack scanning.

Image Quality Review

Image Quality Review

Procedure for reviewing scanned slides to ensure diagnostic quality.

Data Entry

Explains how barcode data is used for automated data entry into the MDDS.

Using the AutoLoader

Microscope Slide Types

Specifies the types of glass microscope slides compatible with the AutoLoader.

Slide Preparation for AutoLoader

Key preparation steps for slides to ensure successful AutoLoader operation.

Loading Slides into the AutoLoader

Step-by-step guide for loading slides into the AutoLoader carousel.

AutoLoader Inspection and Cleaning

Instructions for inspecting and cleaning the AutoLoader and racks.

Quality Control and Maintenance

Maintenance Schedule

Overview of daily, monthly, and annual tasks to maintain scanner performance.

Daily System Checks

Procedures for restarting the controller, presnapping, and setting line camera gains.

Component Cleaning and Maintenance

Guidelines for cleaning the objective, scanner interior, and slide tray.

AutoLoader Sensor Recalibration

Procedure to recalibrate the slide-in-rack sensor for precise positioning.

Service Account Management

Steps to change the service account password and update ApService credentials.

Troubleshooting

General Troubleshooting

Tips for resolving common scanner startup and operational issues.

Scanner Operation Issues

Addresses problems like focus, calibration image errors, and poor scan quality.

AutoLoader Troubleshooting

Solutions for carousel status lights, stalled carousel, and loading errors.

Motion and Magnification Issues

Troubleshooting steps for stage motion faults and magnification changer problems.

Specifications

Operating Environment and Power

Details on recommended workspace conditions and AC power requirements.

Transportation and Disposal

Guidelines for moving, storing, and disposing of the scanner.

Hardware Specifications

Technical specifications for the scanner and AutoLoader components.

Software and System Specs

Information on operating system, software, and system requirements.

Safety Instructions

General Safety Precautions

Essential safety measures for operating the scanner safely.

Specific Safety Guidelines

Covers electrical, environmental, and operational safety directives.

Symbols Reference

Usage and Identification Symbols

Definitions for symbols indicating usage, manufacturing, and identification.

Hazard and Warning Symbols

Explanation of symbols related to biological risks, temperature, and electrical hazards.

Leica BIOSYSTEMS Aperio AT2 DX Specifications

General IconGeneral
BrandLeica BIOSYSTEMS
ModelAperio AT2 DX
CategoryLaboratory Equipment
LanguageEnglish