EasyManua.ls Logo

Lennox Hearth Products ELDV-35NM - User Manual

Lennox Hearth Products ELDV-35NM
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
™
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATEUR : Laissez cette notice avec l'appareil.
CONSOMMATEUR : Conservez cette notice pour consultation ultérieure.
MODELS
DON’T
THROW
IT AWAY!
This manual contains
important operating
and safety
information.
Wait...
ELDV Direct-Vent
Gas Fireplaces
CARE AND OPERATION INSTRUCTIONS
▪
F
▪
R
▪
E
▪
E
▪
▪
See Page 2 For Details
▪
SAFETY
GU ARD
PROTECTS AGAINST BURNS
AVERTISSEMENT : Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d’incindie ou d’explosion ou pour
éviter tout dommage matériel, toute blessure ou la mort.
- Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs
ou liquides inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bâtiment où vous trouvez.
• Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
-
L’installation et l’entretien doivent être assurés par un
installateur ou un service d’entretien qualifié ou par le
fournisseur de gaz.
WARNING: If the information in these instructions
is not followed exactly, a fire or explosion may
result, causing property damage, personal injury,
or death.
-
vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
•
department.
- Installation and service must be performed by a
WARNING
/
AVERTISSEMENT
/
AVISO
• HOT GLASS WILL CAUSE
BURNS.
• DO NOT TOUCH GLASS
UNTIL COOLED.
• NEVER ALLOW CHILDREN
TO TOUCH GLASS.
• UNE SURFACE VITRÉE CHAUDE
PEUT CAUSER DES BRÛLURES.
• LAISSER REFROIDIR LA SURFACE
VITRÉE AVANT D'Y TOUCHER.
• NE PERMETTEZ JAMAIS À UN ENFANT
DE TOUCHER LA SURFACE VITRÉE.
• EL VIDRIO CALIENTE
CAUSARÁ QUEMADURAS.
• USTED DEBE NUNCA
TOCAR EL VIDRIO CALIENTE.
• LOS NIÑOS DEBEN NUNCA
TOCAR EL VIDRIO.
P/N 875030M Rev. E 01/2011
This manual is one of a set of two supporting this product.
Refer to P/N 850036M for Installation Instructions.
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 875030CF.
Table of Contents .................................... 2
Safety and Your Fireplace ............................. 2
FREE Safety Guard Offer
(Protects Against Burns) ............. 2
Important Safety Information .......................... 4
Attaching the Safety-in-Operation Warnings .............. 5
[EN FRANÇAIS] L’information de sûreté importante ............ 3–4
Apposition des mises en garde relatives à la sécurité d’utilisation ... 5
[EN ESPAÑOL] Información importante de seguridad............ 3–4
Colocación de advertencias de seguridad en operación .......... 5
WHAT'S INSIDE
OTL Report No. 116-F-39C-5
US
Portland
ELDV-35NM
ELDV-40NM
ELDV-45NM
ELDV-35PM
ELDV-40PM
ELDV-45PM
MILLIVOLT:
ELDV-35NE
ELDV-40NE
ELDV-45NE
ELECTRONIC:
f i r e - p a r t s . c o m

Questions and Answers

  • D
    Donald FloresAug 7, 2025
    What to do if the main burner does not light on my Lennox Hearth Products Indoor Fireplace?
    • W
      William FrederickAug 7, 2025
      If the main burner on your Lennox Hearth Products Indoor Fireplace doesn't light even when the igniter is sparking, here's what to check: * Ensure the gas supply is turned on. * Make sure the sensor wire connection is secure. * Verify that the black, green, and orange wires are securely connected to the valve. * Confirm the black sensor wire (S) and black igniter wire (I) are securely connected to the ignition module. * Purge any air from the gas line. * Test the voltage at the AC terminals of the module and/or batteries, ensuring it's around 2.7 to 3.2 VAC.
  • A
    Allison PadillaAug 15, 2025
    Why does the main burner on my Lennox Hearth Products ELDV-35NM turn on and then off?
    • S
      Samantha RochaAug 15, 2025
      If the main burner of your Lennox Hearth Products Indoor Fireplace turns on but then shuts off, consider these potential causes: * Ensure the gas supply is turned to the "ON" position. * Check all wire connections on the valve and ignition module to ensure they are secure. * Verify that the flame properly engulfs the flame sensor. * Inspect the vent system for any obstructions.
  • J
    John CunninghamAug 20, 2025
    What to do if pilot will not stay lit on Lennox Hearth Products ELDV-35NM?
    • C
      castillorobertAug 20, 2025
      If your Lennox Hearth Products Indoor Fireplace pilot light won't stay lit after following the lighting instructions, the issue might be a defective pilot generator (thermocouple). Ensure the pilot flame impinges directly on the thermocouple. Clean and/or adjust the pilot for maximum flame impingement on the thermocouple. Also, check that the connection between the valve and thermocouple is tight and secure.
  • D
    Derek WashingtonAug 29, 2025
    Why does my Lennox Hearth Products ELDV-35NM have frequent pilot/burner outages?
    • A
      Anthony SimmonsAug 29, 2025
      If you're experiencing frequent pilot/burner outages with your Lennox Hearth Products Indoor Fireplace, it could be due to the pilot flame being too low or too high, causing the pilot/valve safety to drop out. Clean and/or adjust the pilot flame to ensure maximum flame impingement on the thermocouple.
  • S
    Samuel BakerSep 2, 2025
    What to do if nothing happens when turning on Lennox Hearth Products ELDV-35NM?
    • M
      Mckenzie MartinezSep 2, 2025
      If nothing happens when you turn on the ON/OFF switch (and the pilot does not spark) on your Lennox Hearth Products Indoor Fireplace, here’s what to investigate: * Check the voltage on the AC terminals of the module and/or batteries. It should be around 2.7 to 3.2 VAC. Also, ensure that all wire connections are secure. * Inspect the igniter wire for any visible damage, such as cracked casing or cuts. * Examine the pilot assembly for any visibly broken components, like a broken spark electrode. * Check the voltage on the DC terminal of the batteries. The value should be around 3.0V.
  • J
    Jenny RiveraNov 11, 2025
    How to fix a spark igniter that won't light the pilot on my Lennox Hearth Products ELDV-35NM Indoor Fireplace?
    • J
      James WiseNov 11, 2025
      If the pilot light won't ignite on your Lennox Hearth Products Indoor Fireplace after repeatedly pressing the igniter button, here’s what you should investigate: * Check for a spark at the electrode and pilot. If there's no spark and the electrode wire is properly connected, the igniter may be defective and need replacement. * Light the pilot with a match. If it lights, turn it off and try the igniter button again. If it lights this time, the initial issue was likely due to an improper gas mixture, suggesting a longer purge period. If it still doesn't light, check the gap at the electrode and pilot; it should be 1/8" for a strong spark. If the gap is correct, the pilot might need replacing. * Verify that the inlet gas pressure is within the limits specified on the rating plate. * ...
  • G
    Gary AlexanderNov 23, 2025
    Why is there no gas to the burner on my Lennox Hearth Products ELDV-35NM Indoor Fireplace?
    • C
      Curtis FarrellNov 23, 2025
      If the pilot is burning but no gas is going to the burner on your Lennox Hearth Products Indoor Fireplace, and the valve knob and burner switch are both "ON", here's what to check: * Inspect the wall switch and its wiring for proper connections. To test the switch, use a jumper wire across the terminals at the wall switch. If the burner comes on, the wall switch is defective and needs replacement. If the switch is okay, use jumper wires across the wall switch wires at the valve; if the burner then comes on, the wires or their connections are faulty. * Use a millivolt meter to check the thermopile at the gas valve terminals. It should read a minimum of 325 millivolts with the optional wall switch in the “OFF” position. Replace the thermopile if the reading is below this minimum. * Ch...

Lennox Hearth Products ELDV-35NM Specifications

General IconGeneral
BrandLennox Hearth Products
ModelELDV-35NM
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals