506694-01 Issue 1720 Page 1 of 16
Save these instructions for future reference
INSTALLATION INSTRUCTIONS
13ACD Split System Air Conditioner
with Dry Nitrogen Holding Charge
215 Metropolitan Drive
West Columbia, SC 29170
This manual must be left with the homeowner for future reference.
This is a safety alert symbol and should never be ignored. When you see this symbol on labels or in
manuals, be alert to the potential for personal injury or death.
Table of Contents
General ........................................................................2
Unit Dimensions - inches (mm) ...................................2
Parts Arrangement.......................................................2
Shipping and Packing List ...........................................3
Torque Requirements ..................................................3
Operating Gauge Set and Service Valves ...................3
Recovering Refrigerant from Existing System ............. 4
New Outdoor Unit Placement ......................................5
Replacement Line Set .................................................6
Brazing Connections ...................................................7
Removing Existing Metering Device and Flushing Line
Set and Indoor Coil ....................................................10
Installing New Indoor Metering Device ...................... 11
Leak Test Line Set and Indoor Coil ............................ 12
Evacuating Line Set, Indoor Coil and Outdoor Unit ... 13
Electrical ....................................................................14
Servicing Outdoor Unit Delivered Void of Nitrogen
Charge .......................................................................15
Maintenance ..............................................................15
This unit is factory-charged with dry nitrogen. The
unit is intended for installation in existing HCFC-22
systems. Carefully follow all installation procedures.
Open both service valves to evacuate system. This
unit is constructed without a factory installed lter drier.
Field-provided liquid line lter drier should be installed
per Figure 6A.
NOTE
Installation or repairs made by unqualied persons can
result in hazards to you and others. Installation MUST
conform with local building codes or, in the absence of
local codes, with the National Electrical Code NFPA
70/ANSI C1-1993 or current edition and Canadian
Electrical Code Part 1 CSA C22.1.
WARNING
Improper selection of a matching indoor unit and
a matching metering device, improper installation,
adjustment, alteration, service or maintenance may void
the warranty. The qualied installer or agency must use
factory-authorized kits or accessories when modifying
this products. Refer to the individual instructions
packaged with the kits or accessories when installing.
CAUTION
These instructions are intended as a general guide and
do not supersede national, state or local codes in any
way.
NOTE
This product contains a chemical known to the State
of California to cause cancer, birth defects or other
reproductive harm.
WARNING
Question and Answer IconNeed help?

Do you have a question about the Lennox 13ACD-060-230 and is the answer not in the manual?

Lennox 13ACD-060-230 Specifications

General IconGeneral
BrandLennox
Model13ACD-060-230
CategoryAir Conditioner
LanguageEnglish

Summary

Service Valve Operation Guide

Refrigerant Recovery from Existing Systems

Outdoor Unit Placement and Clearances

Mandatory Installation Clearances

Details minimum air clearances needed around the outdoor unit for proper operation and maintenance.

Unit Placement and Slab Mounting

Provides guidance on positioning the unit relative to structures and ensuring proper slab slope.

Positioning Considerations and Line Set

Replacement Refrigerant Line Set

Provides information and specifications for selecting and installing replacement refrigerant line sets.

Brazing Connections Safety Precautions

Brazing Procedure: Preparation Steps

Brazing Procedure: Execution Steps

Metering Device Removal and System Flushing

Installing Indoor Metering Devices

Leak Test Line Set and Indoor Coil

Perform Leak Test

Detailed steps for performing a leak test on the system using HCFC-22 and pressurized nitrogen.

Evacuating Line Set, Indoor Coil, and Outdoor Unit

Evacuate the System

Detailed steps for evacuating the system to specified micron levels using a vacuum pump and nitrogen.