507266-05 Page 49 of 58Issue 1933
95G2UH090CV12
Temp. Rise Speed Adjustment
Heating CFM @ 0 - 0.8” w.c.
Setting D Setting C Setting B Setting A
High Fire
60-90
+ 1060 1135 1240 1315
Normal 960 1040 1120 1199
- 830 935 980 1084
Low Fire
35-65
+ 960 1040 1120 1206
Normal 875 945 995 1100
- 790 840 920 950
Cooling Stage Cooling CFM @ 0 - 0.8” w.c.
2nd Stage
+ 875 1040 1210 1360
Normal 800 945 1100 1245
- 720 840 970 1115
1st Stage
+ 625 710 830 950
Normal 565 670 760 860
- 520 610 685 785
95G2UH090CV20
Temp. Rise Speed Adjustment
Heating CFM @ 0 - 0.8” w.c.
Setting D Setting C Setting B Setting A
High Fire
40-70
+ 1450 1565 1725 1865
Normal 1310 1450 1585 1690
- 1155 1305 1450 1545
Low Fire
30-60
+ 1120 1265 1420 1520
Normal 965 1120 1285 1395
- 865 950 1120 1235
Cooling Stage Cooling CFM @ 0 - 0.8” w.c.
2nd Stage
+ 1385 1595 1820 2020
Normal 1225 1465 1645 1885
- 1065 1320 1505 1675
1st Stage
+ 935 1055 1275 1465
Normal 835 980 1120 1335
- 740 870 1010 1150