• 11 •
l/h kPa kW kW kW
10 °C
1010 15 --- --- --- 6,28 3,43
1450 25 --- --- --- 6,49 3,48
2070 40 --- --- --- 6,62 3,52
15 °C
1010 15 7,43 6,27 0,66 7,03 3,62
1450 25 7,51 6,56 0,66 7,24 3,67
2070 40 7,55 6,83 0,66 7,40 3,70
20 °C
1010 15 7,20 5,31 0,67 7,77 3,76
1450 25 7,28 5,57 0,66 8,00 3,80
2070 40 7,33 5,80 0,66 8,17 3,82
25 °C
1010 15 6,94 4,49 0,68 8,51 3,85
1450 25 7,03 4,72 0,67 8,75 3,88
2070 40 7,08 4,91 0,67 8,95 3,89
30 °C
1010 15 6,66 3,80 0,69 --- ---
1450 25 6,75 4,00 0,68 --- ---
2070 40 6,81 4,14 0,68 --- ---
35 °C
1010 15 6,36 3,25 0,70 --- ---
1450 25 6,45 3,41 0,69 --- ---
2070 40 6,51 3,52 0,69 --- ---
40 °C
1010 15 6,04 2,82 0,71 --- ---
1450 25 6,13 2,96 0,71 --- ---
2070 40 6,20 3,02 0,70 --- ---
l/h kPa kW kW kW
10 °C
1210 20 --- --- --- 7,56 3,43
1730 30 --- --- --- 7,79 3,47
2470 50 --- --- --- 7,93 3,51
15 °C
1210 20 8,85 5,86 0,66 8,41 3,59
1730 30 8,95 6,09 0,65 8,65 3,63
2470 50 9,01 6,30 0,65 8,81 3,66
20 °C
1210 20 8,55 5,05 0,66 9,25 3,72
1730 30 8,65 5,26 0,66 9,50 3,75
2470 50 8,71 5,45 0,66 9,68 3,77
25 °C
1210 20 8,23 4,34 0,67 10,08 3,79
1730 30 8,33 4,54 0,67 10,34 3,82
2470 50 8,40 4,69 0,67 10,55 3,83
30 °C
1210 20 7,90 3,73 0,68 --- ---
1730 30 8,00 3,90 0,68 --- ---
2470 50 8,07 4,03 0,68 --- ---
35 °C
1210 20 7,55 3,21 0,69 --- ---
1730 30 7,65 3,36 0,69 --- ---
2470 50 7,73 3,46 0,69 --- ---
40 °C
1210 20 7,18 2,78 0,70 --- ---
1730 30 7,29 2,91 0,70 --- ---
2470 50 7,37 2,98 0,70 --- ---
AWH 007
1.250 m
3
/h
AWH 008
1.500 m
3
/h
AQUALEAN - AWC/AWH - MIL118E-1407 / 10-2013
1.8.- CAPACITY TABLES
Water fl ow
Water
pressure drop
AWC/AWH
COOLING CAPACITY
AWH
HEATING CAPACITY
Total capacity EER Sensible/Total Total capacity
Total absorbed
power
Water inlet temperature
Minimum
Nominal
Maximum
Minimum
Nominal
Maximum
Minimum
Nominal
Maximum
Minimum
Nominal
Maximum
Minimum
Nominal
Maximum
Minimum
Nominal
Maximum
Minimum
Nominal
Maximum
Water fl ow
Water
pressure drop
AWC/AWH
COOLING CAPACITY
AWH
HEATING CAPACITY
Total capacity EER Sensible/Total Total capacity
Total absorbed
power
Water inlet temperature
Minimum
Nominal
Maximum
Minimum
Nominal
Maximum
Minimum
Nominal
Maximum
Minimum
Nominal
Maximum
Minimum
Nominal
Maximum
Minimum
Nominal
Maximum
Minimum
Nominal
Maximum
Nominal operating conditions:
Exchanger air inlet temperature: 27ºC DB/19ºC WB in cooling mode and 20ºC WB
in heating mode.
(DW:dry bulb / WB:wet bulb)
For another working conditions use correction factor tables.
GENERAL CHARACTERISTICS
Nominal airfl ow rate
Nominal airfl ow rate