Do you have a question about the Lennox BAH020SNM and is the answer not in the manual?
Cooling Capacity (BTU/h) | 20000 |
---|---|
SEER | 16 |
Voltage (V) | 208/230 |
Stages | Single |
SEER Rating | 16 |
Phase | 1 |
Refrigerant | R-410A |
Checks to ensure equipment is in good working order upon receipt.
Provides model reference, electrical specs, year, refrigerant type, and charge.
Procedures for medium to long-term storage to maintain equipment integrity.
Specifies required equipment for safe handling and lifting of units.
Table detailing unit dimensions (A, B, C, D) and weights for various models.
Diagrams showing lifting configurations for different unit boxes (B, C, D, E).
Dimensions and weights for adjustable and exhaust roof curbs.
Dimensions and weights for multidirectional roof curbs.
Checklist of essential points to verify before installing the unit.
Guidelines for the installation surface and unit placement.
Table showing required clearances for different unit boxes.
Recommendations for positioning adjustable roof mounting frames.
Explains frame parts and installation for non-adjustable roof mounting frames.
Details the assembly and securing process for the non-adjustable roof curb.
Instructions for securing the roof curb assembly.
Guidance on insulation, counter flashing, and sealing for curbs.
Step-by-step guide for installing the heat recovery module.
Explanation of the economiser function for free cooling.
Description of extraction system function and fan operation.
Diagram showing vertical flow configuration with energy recovery and exhaust roofcurb.
Diagram showing multidirectional roofcurb configuration.
Ensuring power supply and checking wire connections for tightness.
Checks for motors, pulleys, wiring, and temperature probes.
Steps for starting the unit using a maintenance controller.
Procedures for powering up the unit and checking fan rotation.
Performing cooling mode run tests and safety checks.
Table and diagrams showing options for BAC/BAH models.
Diagrams and options for BAG/BAM models.
Diagrams and options for BAC/BAH 035 models.
Diagrams and options for BAG/BAM 035 models.
Diagrams and options for BAC/BAH 045/055 models.
Diagrams and options for BAG/BAM 045/055 models.
Diagrams and options for BAC/BAH 065/075 models.
Diagrams and options for BAG/BAM 065/075 models.
Table for dimensions and power entry points for all units.
Dimensions for BAC/BAH/BAG/BAM models 020 and 030.
Dimensions for BAC/BAH/BAG/BAM model 035.
Dimensions for BAC/BAH/BAG/BAM models 045 and 055.
Dimensions for BAC/BAH/BAG/BAM models 065 and 075.
Diagrams and dimensions for models 020 and 030.
Diagrams and dimensions for model 035.
Diagrams and dimensions for models 045 and 055.
Diagrams and dimensions for models 065 and 075.
Diagrams and dimensions for models 020 and 030.
Diagrams and dimensions for model 035.
Diagrams and dimensions for models 045 and 055.
Diagrams and dimensions for models 065 and 075.
Diagrams and dimensions for models 020, 030, and 035.
Diagrams and dimensions for models 045 and 055.
Diagrams and dimensions for models 065 and 075.
Diagrams and dimensions for models 065 and 075.
Diagrams for energy recovery option for models 020 and 030.
Diagrams for energy recovery option for model 035.
Diagrams for energy recovery option for models 045 and 055.
Diagrams for energy recovery option for models 065 and 075.
Instructions for checking and adjusting belt tension and pulley alignment.
Steps for fan pulley removal and installation.
Procedures for motor pulley installation and removal.
How to check pulley alignment after adjustment.
Guidance on measuring motor absorbed power for airflow adjustment.
Estimating airflow, total pressure, and external static pressure using fan curves.
Table of pressure drops for various accessories and unit sizes.
Detailed example of calculating fan performance and ESP.
Performance curves for AT12-9S units.
Performance curves for AT15-11S units.
Performance curves for AT15-15S units.
Performance curves for AT15-11G2L units.
Performance curves for AT10-10S units.
Performance curves for AT10-8G2L units.
Performance curves for AT10-10G2L units.
Instructions for removing and replacing filters and controller set points.
Guide to navigating the fan control menus for quick settings.
Steps for connecting and filling the hot water coil system.
Measures for freeze protection, including glycol and draining.
Warning about corrosion due to unbalanced earth connections.
Table of internal pipe diameters for different model sizes.
Overview of electric heaters, sizes, and control methods.
Safety checks and compatibility considerations before commissioning gas burners.
Steps for starting the gas burner and setting room temperature.
Timeline of operations during the gas burner start-up sequence.
Procedure for adjusting gas pressure on the regulating valve.
Steps to check and adjust outlet pressure for high heat injection.
Procedure to check and adjust outlet pressure for low heat.
Tests for smoke extractor pressure switch, gas pressure switch, and ionisation probe.
Flowchart detailing the sequence of operations for gas burner start-up.
Troubleshooting guide for gas burner faults reported on CLIMATIC.
Table mapping fault stages to possible actions and solutions.
Safety recommendations and steps for disassembling the gas burner.
Explanation of the modulating gas actuator and its function.
Procedure for starting up the modulating gas burner.
Adjusting gas pressure on the regulating valve for modulating burners.
Checking and adjusting outlet pressure for high heat in modulating burners.
Checking and adjusting outlet pressure for low heat in modulating burners.
Safety checks for modulating gas burners.
Troubleshooting for modulating gas burner valve flow issues.
Steps for disassembling modulating gas burners for maintenance.
Details on connecting sensors, displays, and communication interfaces.
Configuring digital and analog inputs/outputs for unit control.
Setting up time zones, schedules, and clock settings for unit operation.
Overview and operation of the DC50/DM50 customer display units.
Mapping of BMS addresses for ModBus, Trend, BACnet, and Carel protocols.
List and explanation of error codes for the Climatic system.
Refrigerant circuit diagram for BAH models 020-030.
Refrigerant circuit diagram for BAC models 020-030.
Refrigerant circuit diagram for BAH models 035-055.
Refrigerant circuit diagram for BAC models 035-055.
Refrigerant circuit diagram for BAH models 065-075.
Refrigerant circuit diagram for BAC models 065-075.
Notes on supply pressure and temperature for the hot water coil.
Troubleshooting guide for refrigeration system faults and cut-outs.
Diagnosing low pressure issues and cut-outs.
Troubleshooting for high pressure issues and cut-outs.
Troubleshooting guide for indoor fan blower faults.
Troubleshooting guide for outdoor axial fan faults.
Troubleshooting for electric heater faults.
Diagnosing and resolving water leaks in the unit.
Troubleshooting communication and display issues for DC50/DS50.
Explanation of symbols used in the maintenance plan.
Important notes regarding maintenance procedures and parts.
General warranty terms and period.
10-year warranty against casing corrosion and exclusions.
Clarifies warranty applicability based on maintenance contracts.
Certificate details for ISO 9001:2000 compliance.
CE conformity declaration for European directives.
NF certification for fire safety components.
Certification for optical smoke detectors.
Fire reaction classification report for materials.
Fire reaction classification report for materials.
Fire reaction classification report for materials.
Fire reaction classification report for materials.
Gas appliance certification details.
Quality system approval attestation.
Annex to the quality system approval attestation.