EasyManua.ls Logo

Lennox CBA25UHV-036 User Manual

Lennox CBA25UHV-036
33 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Page 1
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, personal
injury or loss of life. Installation and service must be
performed by a licensed professional HVAC installer or
equivalent, service agency, or the gas supplier.
IMPORTANT
The Clean Air Act of 1990 bans the intentional venting of
refrigerant (CFCs, HCFCs and HFCs) as of July 1, 1992.
Approved methods of recovery, recycling or reclaiming
must be followed. Fines and/or incarceration may be
levied for noncompliance.
NOTICE
A thermostat is not included and must be ordered
separately.
A Lennox communicating thermostat must be used in
communicating applications.
In non-communicating applications, the Lennox
ComfortSense® thermostat may be used, as well as
other non-communicating thermostats.
In all cases, setup is critical to ensure proper system
operation.
Field wiring for both communicating and non-
communicating applications is illustrated in diagrams,
which begin on page 29.
CAUTION
As with any mechanical equipment, contact with sharp
sheet metal edges can result in personal injury. Take
care while handling this equipment and wear gloves and
protective clothing.
CBA25UHV
IMPORTANT: Special procedures are required for clean-
ing the all-aluminum coil in this unit. See page 30 in this
instruction for information.
Table of Contents
CBA25UHV Unit Dimensions – Upow – inches (mm)...2
Specications and Electrical Data ..................................3
Model Number Identication ...........................................4
Adjusting the BDC3 Blower Control ...............................4
Adjusting the Blower Speed ..........................................4
Blower Data ....................................................................6
Application ....................................................................10
Unit Components ..........................................................10
ECBA25 Electric Heat Data ..........................................12
Heat Section Installation ...............................................17
Conguration Modication ........................................... 19
Brazing Connections ...................................................22
Installing the Condensate Drain ..................................24
Electrical Connections ................................................. 26
Inspecting and Replacing Filters .................................27
Wiring Diagrams ...........................................................28
Professional Maintenance ...........................................30
Check-out Procedures .................................................30
Sequence of Operation ................................................31
Service Literature
UNIT INFORMATION
Corp. 1917-L9
September 20, 2019
CBA25UHV (HFC-410A) SERIES UNITS
General Information
This indoor unit with all-aluminum coil is designed for
installation with optional eld-installed electric heat and a
matched outdoor unit that is charged with HFC-410A re-
frigerant. These units, designed for indoor installation in
multiple positions, are completely assembled for upow
and horizontal right-hand discharge before being shipped
from the factory.
All CBA25UHV air handlers are equipped with a facto-
ry-installed, internally mounted check / expansion valve,
which is suitable for use in HFC-410A applications.
This air handler is compatible with the ComfortSense®
non-communicating thermostat and non-communicating
outdoor units. In addition, this unit has the enhanced ca-
pability of communicating with communicating thermo-
stats and communicating outdoor units using the Lennox
RSBus protocols.
NOTE - For downow or horizontal left-hand air discharge,
certain eld modications are required.
Question and Answer IconNeed help?

Do you have a question about the Lennox CBA25UHV-036 and is the answer not in the manual?

Lennox CBA25UHV-036 Specifications

General IconGeneral
BrandLennox
ModelCBA25UHV-036
CategoryAir Conditioner
LanguageEnglish

Summary

Unit Identification and Blower Control

BDC3 Blower Control Adjustment

Instructions for adjusting the BDC3 variable speed blower control settings.

Blower Speed Adjustment

Details on setting blower speed using jumpers and determining correct CFM.

Blower Speed Jumper Configuration

Adjust Jumper Settings

Explains jumper settings for speed adjustment (+, NORMAL, -) and CFM selection.

Cool Jumper Settings

Details on jumper selections for cooling or heat pump operation based on system type.

Electric Heat Data Tables

Electric Heat Specs (018 & 024)

Provides input, output, and protection data for electric heat kits for specific models.

Heat Section Installation Procedures

Installing Heat Elements

Step-by-step guide for installing electric heat elements into the air handler unit.

Electrical Connections and Circuit Breaker Installation

Electrical Connections

Guidelines for field power supply wiring, connections, and grounding.

Configuration Modifications

Horizontal Application Modifications

Left-Hand Discharge Configuration

Field modification steps for achieving left-hand air discharge.

Right-Hand Discharge Configuration

Steps for setting up the unit for right-hand air discharge.

Downflow Application Modifications

Brazing Connections and Refrigerant Line Requirements

Brazing Connections Procedure

Steps and safety precautions for brazing refrigerant piping, including nitrogen purging.

Condensate Drain Installation Procedures

Typical Drain Installation

Illustrates main and overflow drain line routing, trap requirements, and connections.

Condensate Drain Testing and Duct System

Electrical Connections and Filter Maintenance

Maintenance and Operation Checks

Operational Checks

Procedures to verify proper operation of blower, cooling, and electric heat functions.