EasyManua.ls Logo

Lennox CBA25UHV-042

Lennox CBA25UHV-042
33 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Page 1
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, personal
injury or loss of life. Installation and service must be
performed by a licensed professional HVAC installer or
equivalent, service agency, or the gas supplier.
IMPORTANT
The Clean Air Act of 1990 bans the intentional venting of
refrigerant (CFCs, HCFCs and HFCs) as of July 1, 1992.
Approved methods of recovery, recycling or reclaiming
must be followed. Fines and/or incarceration may be
levied for noncompliance.
NOTICE
A thermostat is not included and must be ordered
separately.
A Lennox communicating thermostat must be used in
communicating applications.
In non-communicating applications, the Lennox
ComfortSense® thermostat may be used, as well as
other non-communicating thermostats.
In all cases, setup is critical to ensure proper system
operation.
Field wiring for both communicating and non-
communicating applications is illustrated in diagrams,
which begin on page 29.
CAUTION
As with any mechanical equipment, contact with sharp
sheet metal edges can result in personal injury. Take
care while handling this equipment and wear gloves and
protective clothing.
CBA25UHV
IMPORTANT: Special procedures are required for clean-
ing the all-aluminum coil in this unit. See page 30 in this
instruction for information.
Table of Contents
CBA25UHV Unit Dimensions – Upow – inches (mm)...2
Specications and Electrical Data ..................................3
Model Number Identication ...........................................4
Adjusting the BDC3 Blower Control ...............................4
Adjusting the Blower Speed ..........................................4
Blower Data ....................................................................6
Application ....................................................................10
Unit Components ..........................................................10
ECBA25 Electric Heat Data ..........................................12
Heat Section Installation ...............................................17
Conguration Modication ........................................... 19
Brazing Connections ...................................................22
Installing the Condensate Drain ..................................24
Electrical Connections ................................................. 26
Inspecting and Replacing Filters .................................27
Wiring Diagrams ...........................................................28
Professional Maintenance ...........................................30
Check-out Procedures .................................................30
Sequence of Operation ................................................31
Service Literature
UNIT INFORMATION
Corp. 1917-L9
September 20, 2019
CBA25UHV (HFC-410A) SERIES UNITS
General Information
This indoor unit with all-aluminum coil is designed for
installation with optional eld-installed electric heat and a
matched outdoor unit that is charged with HFC-410A re-
frigerant. These units, designed for indoor installation in
multiple positions, are completely assembled for upow
and horizontal right-hand discharge before being shipped
from the factory.
All CBA25UHV air handlers are equipped with a facto-
ry-installed, internally mounted check / expansion valve,
which is suitable for use in HFC-410A applications.
This air handler is compatible with the ComfortSense®
non-communicating thermostat and non-communicating
outdoor units. In addition, this unit has the enhanced ca-
pability of communicating with communicating thermo-
stats and communicating outdoor units using the Lennox
RSBus protocols.
NOTE - For downow or horizontal left-hand air discharge,
certain eld modications are required.
Question and Answer IconNeed help?

Do you have a question about the Lennox CBA25UHV-042 and is the answer not in the manual?

Lennox CBA25UHV-042 Specifications

General IconGeneral
BrandLennox
ModelCBA25UHV-042
CategoryAir Conditioner
LanguageEnglish

Summary

Specifications and Electrical Data

Blower Control and Speed Adjustment

Adjusting the Blower Speed

Details how to adjust blower speed using jumpers.

Jumper Settings

Adjust Jumper

How to adjust motor speed via jumpers for CFM control.

Cool Jumper

Explains jumper settings for cooling and heat pump CFM.

Blower Performance Data

Electric Heat Data

Data for Models -018 and -024

Electrical specifications for electric heat kits in -018 and -024 models.

Data for Models -030 and -036

Electrical specifications for electric heat kits in -030 and -036 models.

Data for Model -042

Electrical specifications for electric heat kits in the -042 model.

Data for Model -048

Electrical specifications for electric heat kits in the -048 model.

Heat Section Installation

Circuit Breaker and Electrical Connections

Electrical Connection Guidelines

General guidelines for field wiring and connections.

Configuration Modifications

Downflow and Right-Hand Discharge Configurations

Downflow Application

Instructions and requirements for downflow configuration.

Brazing Connections and Procedures

Brazing Process Steps

Detailed steps for performing refrigerant line brazing operations.

Condensate Drain Installation and Testing

Drain Testing and Best Practices

Procedures for testing the drain system and recommended practices.

Unit Sealing and Electrical Connections

Unit Sealing Procedures

Methods to ensure an airtight seal for the unit cabinet.

Electrical Connection Guidelines

General guidelines for field wiring and connections.

Wiring Diagrams

Typical Wiring Diagram (Electric Heat)

Illustrates typical wiring for electric heat configurations.

Low Voltage Connections

Professional Maintenance and Checks

Check-out Procedures

Steps to verify proper installation and operation.

Sequence of Operation

Start-Up and Performance Checklists

Upflow Configuration Checklist

Checklist for verifying upflow installation and performance.

Horizontal Configuration Checklist

Checklist for verifying horizontal installation and performance.

Related product manuals