Page 1
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, personal
injury or loss of life. Installation and service must be
performed by a licensed professional HVAC installer or
equivalent, service agency, or the gas supplier.
IMPORTANT
The Clean Air Act of 1990 bans the intentional venting of
refrigerant (CFCs, HCFCs and HFCs) as of July 1, 1992.
Approved methods of recovery, recycling or reclaiming
must be followed. Fines and/or incarceration may be
levied for noncompliance.
NOTICE
A thermostat is not included and must be ordered
separately.
• A Lennox communicating thermostat must be used in
communicating applications.
• In non-communicating applications, the Lennox
ComfortSense® thermostat may be used, as well as
other non-communicating thermostats.
In all cases, setup is critical to ensure proper system
operation.
Field wiring for both communicating and non-
communicating applications is illustrated in diagrams,
which begin on page 29.
CAUTION
As with any mechanical equipment, contact with sharp
sheet metal edges can result in personal injury. Take
care while handling this equipment and wear gloves and
protective clothing.
CBA25UHV
IMPORTANT: Special procedures are required for clean-
ing the all-aluminum coil in this unit. See page 30 in this
instruction for information.
Table of Contents
CBA25UHV Unit Dimensions – Upow – inches (mm)...2
Specications and Electrical Data ..................................3
Model Number Identication ...........................................4
Adjusting the BDC3 Blower Control ...............................4
Adjusting the Blower Speed ..........................................4
Blower Data ....................................................................6
Application ....................................................................10
Unit Components ..........................................................10
ECBA25 Electric Heat Data ..........................................12
Heat Section Installation ...............................................17
Conguration Modication ........................................... 19
Brazing Connections ...................................................22
Installing the Condensate Drain ..................................24
Electrical Connections ................................................. 26
Inspecting and Replacing Filters .................................27
Wiring Diagrams ...........................................................28
Professional Maintenance ...........................................30
Check-out Procedures .................................................30
Sequence of Operation ................................................31
Service Literature
UNIT INFORMATION
Corp. 1917-L9
September 20, 2019
CBA25UHV (HFC-410A) SERIES UNITS
General Information
This indoor unit with all-aluminum coil is designed for
installation with optional eld-installed electric heat and a
matched outdoor unit that is charged with HFC-410A re-
frigerant. These units, designed for indoor installation in
multiple positions, are completely assembled for upow
and horizontal right-hand discharge before being shipped
from the factory.
All CBA25UHV air handlers are equipped with a facto-
ry-installed, internally mounted check / expansion valve,
which is suitable for use in HFC-410A applications.
This air handler is compatible with the ComfortSense®
non-communicating thermostat and non-communicating
outdoor units. In addition, this unit has the enhanced ca-
pability of communicating with communicating thermo-
stats and communicating outdoor units using the Lennox
RSBus protocols.
NOTE - For downow or horizontal left-hand air discharge,
certain eld modications are required.

Questions and Answers

  • P
    Pat QuinnSep 19, 2026
    Can I use a MERV 11 filter in my 2019 042 unit

    Summary

    Specifications and Electrical Data

    Blower Control and Speed Adjustment

    Adjusting the Blower Speed

    Details how to adjust blower speed using jumpers.

    Jumper Settings

    Adjust Jumper

    How to adjust motor speed via jumpers for CFM control.

    Cool Jumper

    Explains jumper settings for cooling and heat pump CFM.

    Blower Performance Data

    Electric Heat Data

    Data for Models -018 and -024

    Electrical specifications for electric heat kits in -018 and -024 models.

    Data for Models -030 and -036

    Electrical specifications for electric heat kits in -030 and -036 models.

    Data for Model -042

    Electrical specifications for electric heat kits in the -042 model.

    Data for Model -048

    Electrical specifications for electric heat kits in the -048 model.

    Heat Section Installation

    Circuit Breaker and Electrical Connections

    Electrical Connection Guidelines

    General guidelines for field wiring and connections.

    Configuration Modifications

    Downflow and Right-Hand Discharge Configurations

    Downflow Application

    Instructions and requirements for downflow configuration.

    Brazing Connections and Procedures

    Brazing Process Steps

    Detailed steps for performing refrigerant line brazing operations.

    Condensate Drain Installation and Testing

    Drain Testing and Best Practices

    Procedures for testing the drain system and recommended practices.

    Unit Sealing and Electrical Connections

    Unit Sealing Procedures

    Methods to ensure an airtight seal for the unit cabinet.

    Electrical Connection Guidelines

    General guidelines for field wiring and connections.

    Wiring Diagrams

    Typical Wiring Diagram (Electric Heat)

    Illustrates typical wiring for electric heat configurations.

    Low Voltage Connections

    Professional Maintenance and Checks

    Check-out Procedures

    Steps to verify proper installation and operation.

    Sequence of Operation

    Start-Up and Performance Checklists

    Upflow Configuration Checklist

    Checklist for verifying upflow installation and performance.

    Horizontal Configuration Checklist

    Checklist for verifying horizontal installation and performance.

    Lennox CBA25UHV-042 Specifications

    General IconGeneral
    BrandLennox
    ModelCBA25UHV-042
    CategoryAir Conditioner
    LanguageEnglish

    Related product manuals