Page 1
INSTALLATION
INSTRUCTIONS
EL180UHNE
507647-04
08/2021
Supersedes 507646-03
THIS MANUAL MUST BE LEFT WITH THE
HOMEOWNER FOR FUTURE REFERENCE
This is a safety alert symbol and should never be
ignored. When you see this symbol on labels or in man-
uals, be alert to the potential for personal injury or death.
IMPORTANT
DO NOT use the heat exchanger tubes to lift, drag or
pull the furnace to its installation location.
Doing so may damage or bend the tubes causing noise
and or unsafe operation.
HeatExchanger Tubes
© 2021 Lennox Industries Inc.
Dallas, Texas USA
ELITE
®
SERIES GAS FURNACE
UPFLOW / HORIZONTAL AIR DISCHARGE
Contents
Unit Dimensions .............................................................2
EL180UHN Gas Furnace................................................3
Shipping and Packing List ..............................................3
Safety .............................................................................3
Use of Furnace as a Construction Heaterl .....................4
General ...........................................................................5
Combustion, Dilution, Ventilation Air...............................5
Setting Equipment ..........................................................8
Filters ............................................................................ 11
Duct System ................................................................. 11
Venting..........................................................................14
Gas Piping ....................................................................18
Electrical .......................................................................20
Integrated Control .........................................................24
Unit Start-Up .................................................................25
Gas Pressure Measurement.........................................26
Proper Combustion.......................................................26
High Altitude .................................................................26
Other Unit Adjustments.................................................27
Service..........................................................................28
Start-Up Checklist.........................................................30
Blower Data ..................................................................33

Other manuals for Lennox EL180UH080NE48B

Question and Answer IconNeed help?

Do you have a question about the Lennox EL180UH080NE48B and is the answer not in the manual?

Lennox EL180UH080NE48B Specifications

General IconGeneral
ModelEL180UH080NE48B
TypeGas Furnace
Heating Capacity80, 000 BTU/h
Efficiency Rating80%
AFUE Rating80%
Blower MotorPSC
Fuel TypeNatural Gas
StagesSingle Stage
Ignition TypeHot Surface Ignition
Vent TypeConventional

Summary

Unit Dimensions

Safety and Air Requirements

Installation and Handling Safety

Covers critical safety warnings for installation, operation, maintenance, and handling to prevent injury or death.

Combustion Air and Ventilation

Discusses requirements for adequate combustion air, ventilation, and avoiding contaminated or corrosive atmospheres.

Confined Space Air Supply

Details air intake and ventilation requirements for furnaces installed in confined spaces.

Installation and Configuration

Equipment Setting and Clearances

Guidance on selecting installation locations, clearances, and settings for upflow and horizontal applications.

Duct System and Filters

Instructions for duct system design, filter requirements, and proper furnace installation.

Venting Procedures

Details furnace venting requirements, including common venting and using masonry chimneys.

Gas System Installation

Gas Piping and Connections

Details on gas supply connection, pipe sizing, slope, support, and torque requirements.

Gas Pressure and Flow Adjustment

Instructions for gas pressure adjustment, checking manifold pressure, and gas flow rates for proper operation.

Electrical System and Controls

Electrical Safety and Wiring

Covers electrical safety, wiring practices, circuit protection, grounding, and accessory connections.

Integrated Control and Diagnostics

Explains the integrated control system, diagnostic codes, and blower speed adjustments.

Unit Start-Up and Operation

Furnace Start-Up Procedure

Step-by-step guide for safely starting the furnace, including gas valve operation and initial checks.

Operational Checks and Settings

Details checks for heating and cooling modes, including static pressure, temperature, and blower performance.

Service and Maintenance

Annual Maintenance Checklist

Provides essential maintenance tasks to be performed annually by a qualified technician.

Performance Data