Page 50
Requirements for Commonwealth of Massachusetts
0RGL¿FDWLRQVWR1)3$&KDSWHU
Revise NFPA-54 section 10.8.3 to add the following 
requirements:
)RU DOO VLGH ZDOO KRUL]RQWDOO\ YHQWHG JDVIXHOHG HTXLS-
ment installed in every dwelling, building or structure used 
in whole or in part for residential purposes, including those 
owned or operated by the Commonwealth and where the 
side wall exhaust vent termination is less than seven (7) 
IHHWDERYHWKH¿QLVKHGJUDGHLQWKHDUHDRIWKHYHQWLQJLQ-
cluding but not limited to decks and porches, the following 
UHTXLUHPHQWVVKDOOEHVDWLV¿HG
1 -   NSTALLATION OF CARBON MONOXIDE 
DETECTORS. At the time of installation of the side 
ZDOO KRUL]RQWDOO\ YHQWHG JDVIXHOHG HTXLSPHQW
WKHLQVWDOOLQJSOXPEHURUJDV¿WWHUVKDOOREVHUYHWKDW
a hard-wired carbon monoxide detector with an 
DODUP DQG EDWWHU\ EDFNXS LV LQVWDOOHG RQ WKH ÀRRU
level where the gas equipment is to be installed. 
,QDGGLWLRQWKHLQVWDOOLQJSOXPEHURUJDV¿WWHUVKDOO
observe that a battery-operated or hard-wired 
carbon monoxide detector with an alarm is installed 
on each additional level of the dwelling, building or 
VWUXFWXUHVHUYHGE\WKHVLGHZDOOKRUL]RQWDOO\YHQWHG
gas-fueled equipment. It shall be the responsibility 
of the property owner to secure the services of 
TXDOL¿HG OLFHQVHG SURIHVVLRQDOV IRU WKH LQVWDOODWLRQ
of hard-wired carbon monoxide detectors.
a.  ,QWKHHYHQWWKDWWKHVLGHZDOOKRUL]RQWDOO\YHQWHGJDVIXHOHG
equipment is installed in a crawl space or an attic, the hard-
wired carbon monoxide detector with alarm and battery back-
XSPD\EHLQVWDOOHGRQWKHQH[WDGMDFHQWÀRRUOHYHO
b.  In the event that the requirements of this subdivision cannot 
be met at the time of completion of installation, the owner 
shall have a period of thirty (30) days to comply with the 
above requirements; provided, however, that during said 
thirty (30) day period, a battery-operated carbon monoxide 
detector with an alarm shall be installed.
2 -  APPROVED CARBON MONOXIDE DETECTORS. 
Each carbon monoxide detector as required in 
accordance with the above provisions shall comply 
with NFPA 720 and be ANSI/UL 2034 listed and IAS 
FHUWL¿HG
6,*1$*( $ PHWDO RU SODVWLF LGHQWL¿FDWLRQ SODWH
shall be permanently mounted to the exterior of the 
building at a minimum height of eight (8) feet above 
grade directly in line with the exhaust vent terminal 
IRU WKH KRUL]RQWDOO\ YHQWHG JDVIXHOHG KHDWLQJ
appliance or equipment. The sign shall read, in print 
VL]H QR OHVV WKDQ RQHKDOI  LQFK LQ VL]H ³*$6
VENT DIRECTLY BELOW. KEEP CLEAR OF ALL 
OBSTRUCTIONS.”
4 - INSPECTION. The state or local gas inspector of the 
VLGH ZDOO KRUL]RQWDOO\ YHQWHG JDVIXHOHG HTXLSPHQW
shall not approve the installation unless, upon 
inspection, the inspector observes carbon monoxide 
detectors and signage installed in accordance with the 
provisions of 248 CMR 5.08(2)(a) 1 through 4.
EXEMPTIONS: The following equipment is exempt 
from 24 CMR 5.08(2)(a) 1 through 4:
1 -   The equipment listed in Chapter 10 entitled 
“Equipment Not Required to Be Vented” in the most 
current edition of NFPA 54 as adopted by the Board; 
and
3URGXFW $SSURYHG VLGH ZDOO KRUL]RQWDOO\ YHQWHG
gasfueled equipment installed in a room or structure 
separate from the dwelling, building or structure used 
in whole or in part for residential purposes.
MANUFACTURER REQUIREMENTS -
GAS EQUIPMENT VENTING SYSTEM PROVIDED.
When the manufacturer of Product Approved side wall, 
KRUL]RQWDOO\ YHQWHG JDVIXHOHG HTXLSPHQW SURYLGHV D
venting system design or venting system components 
with the equipment, the instructions provided by the man-
ufacturer for installation of the equipment and the venting 
system shall include:
1 -   Detailed instructions for the installation of the venting 
system design or the venting system components: 
and
2 - A complete parts list for the venting system design or 
venting system.
MANUFACTURER REQUIREMENTS -
GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED.
When the manufacturer of Product Approved side wall, 
KRUL]RQWDOO\ YHQWHG JDVIXHOHGHTXLSPHQW GRHV QRW SUR-
YLGH WKH SDUWV IRU YHQWLQJ WKH ÀXH JDVHV EXW LGHQWL¿HV
“special venting systems,” the following requirements 
VKDOOEHVDWLV¿HGE\WKHPDQXIDFWXUHU
1 -   The referenced “special venting system” instructions 
shall be included with the appliance or equipment 
installation instructions; and
2-  The “special venting systems” shall be Product 
Approved by the Board, and the instructions for 
that system shall include a parts list and detailed 
installation instructions.
A copy of all installation instructions for all Product 
Approved side wall, horizontally vented, gas-fueled 
equipment, all venting instructions, all parts lists for  
venting instructions, and/or all venting design instruc-
tions shall remain with the appliance or equipment at 
the completion of the installation.