Page 6
6HUYLFH5HPLQGHU
Call your Lennox service technician if the unit will not op-
erate. Before calling, always check the following to be 
sure service is required:
1 -   Check that electrical disconnect switches are ON.
2 -   Check room thermostat for proper setting.
3 -   Replace any blown fuses or reset circuit breakers.
4 -   Gas valve should be ON.
5 -  $LU¿OWHUVKRXOGQRWEH SOXJJHGZKLFKZLOO OLPLWDLU
ÀRZ
6 -   Is gas turned on at meter?
7 -  ,VPDQXDOPDLQVKXWRႇYDOYHRSHQ"
Record the model and serial number of the furnace. These 
numbers are on the unit nameplate, which is located on 
the blower deck below the combustion air inducer.
Serial Number __________________
Model Number __________________
6DIHW\3UHFDXWLRQV
,I \RX GLVFRYHU DQ\ RI WKH IROORZLQJ VKXW GRZQ \RXU
XQLWDQGFRQWDFWD/HQQR[GHDOHUIRUDQLQVSHFWLRQE\
DOLFHQVHGSURIHVVLRQDOVHUYLFHWHFKQLFLDQRUHTXLYD-
OHQW
•  If you repeatedly hear any new or unfamiliar sounds 
while your unit is operating, there may be a prob-
lem. For example, poorly performing burners can 
produce unfamiliar noises.
•   If you smell any unusual odors, your unit may be 
operating improperly. For example, units can give 
RႇXQIDPLOLDURGRUVLIFRPSRQHQWVDUHUHTXLUHGWR
operate in abnormal conditions.
•   Look for visible signs of a malfunctioning unit. Ex-
amples include unusual amounts of condensate on 
windows inside your house, visibly burnt compo-
nents or unusual dirt or rust accumulations on the 
vent pipe or in the unit.
•   If you experience headache, nausea, fatigue, or 
dizziness, the cause could be exposure to carbon 
monoxide gas. This is often misdiagnosed as the 
ÀXEHFDXVHV\PSWRPVDUHVLPLODU,I\RXVXႇHUIURP
ÀXOLNH V\PSWRPV WKDW DUH H[DJJHUDWHG DW KRPH
but seem to subside while you are away from the 
house, exposure to carbon monoxide could be the 
cause.
<RXUYLJLODQFHPD\SD\RႇLQHDUO\GHWHFWLRQRIDSUREOHP
before either personal injury or property damage occurs. 
'RQRWKHVLWDWHWRFRQWDFWDTXDOL¿HGVHUYLFHWHFKQLFLDQDV
an investment in your well being.
3ODQQHG6HUYLFH
Annual Furnace Maintenance
At the beginning of each heating season, and to comply 
with the Lennox Limited Warranty, your system should 
be checked as follows by a licensed professional service 
technician (or equivalent).
1 -   Check wiring for loose connections, voltage at 
indoor unit and amperage of indoor motor.
2 -   Check the condition of the belt and shaft bearings 
if applicable.
3 -   Inspect all gas pipe and connections for leaks.
4 -  &KHFN WKH FOHDQOLQHVV RI ¿OWHUV DQG FKDQJH LI
necessary (monthly).
5 -   Check the condition and cleanliness of burners and 
heat exchanger and clean if necessary.
6 -   Check the cleanliness of blower assembly and 
clean the housing, blower wheel and blower motor 
if necessary.
7 -   Inspect the condensate drain and trap for leaks and 
cracks. The drain and trap must also be cleaned 
and the trap must be primed with water. Inspect the 
rubber hoses connected to the pressure switches for 
cracks or loose connections, replace as necessary. 
Remove the rubber hoses from the cold end header 
box and inspect for any blockage, clean as needed. 
If strainers are installed in the hoses remember to 
remove and clean before reinstalling the hoses.
8 -   Evaluate the heat exchanger integrity by inspecting 
the heat exchanger per the AHRI heat exchanger 
inspection procedure. This procedure can be 
viewed at www.ahrinet.org
 (QVXUHVXႈFLHQWFRPEXVWLRQDLULVDYDLODEOHWRWKH
furnace. Fresh air grilles and louvers (on the unit 
and in the room where the furnace is installed) 
must be properly sized, open and unobstructed to 
provide combustion air.
10 -  Inspect the furnace intake and exhaust pipes to 
make sure they are in place, structurally sound, 
without holes, blockage or leakage and the 
exhaust pipe is sloped toward the furnace. Inspect 
terminations to ensure they are free of obstructions 
and are structurally sound. Inspect the furnace 
return air duct connection to ensure the duct is 
sealed to the furnace. Check for air leaks on supply 
and return ducts and seal where necessary.
NOTE - $IWHUDQ\KHDY\VQRZLFHRUIUR]HQIRJHYHQWWKH
IXUQDFHYHQWSLSHVPD\EHFRPHUHVWULFWHG$OZD\VFKHFN
WKHYHQWV\VWHPDQGUHPRYHDQ\VQRZRULFHWKDWPD\EH
REVWUXFWLQJWKHSODVWLFLQWDNHRUH[KDXVWSLSHV