AIR FLOW
UPFLOW
AIR FLOW
AIR FLOW
HORIZONTAL RIGHT
HORIZONTAL LEFT
CAUTION
As with any mechanical equipment, personal injury
can result from contact with sharp sheet metal
edges. Be careful when you handle this equipment.
INSTALLATION
INSTRUCTIONS
EL296UHV
ELITE
®
SERIES GAS FURNACE
UPFLOW / HORIZONTAL AIR DISCHARGE
507264-01
07/2014
Supersedes 05/2014
THIS MANUAL MUST BE LEFT WITH THE
HOMEOWNER FOR FUTURE REFERENCE
This is a safety alert symbol and should never be ignored.
When you see this symbol on labels or in manuals, be alert
to the potential for personal injury or death.
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, person
al injury or loss of life. Installation and service must
be performed by a licensed professional HVAC in
staller (or equivalent), service agency or the gas sup
plier.
NOTICE
A thermostat is not included and must be ordered
separately.
The Lennox icomfort Wi-Fi
®
thermostat must be
used in communicating applications.
In non-communicating applications, the Lennox
ComfortSense
®
7000 thermostat may be used, as
well as other non-communicating thermostats.
In all cases, setup is critical to ensure proper system
operation.
Field wiring for both communicating and non-com
municating applications is illustrated in diagrams,
which begin on Page 41.
Table of Contents
Unit Dimensions 2................................
EL296UHV Gas Furnace 3.........................
Shipping and Packing List 3........................
Safety Information 3...............................
Use of Furnace as a Construction Heater 4...........
General 5........................................
Combustion, Dilution, Ventilation Air 5...............
Setting Equipment 8...............................
Filters 13..........................................
Duct System 13....................................
Pipe and Fittings Specifications 13...................
Joint Cementing Procedure 15.......................
Venting Practices 16...............................
Gas Piping 36.....................................
Electrical 39.......................................
Integrated Control 48...............................
Blower Motor Performance 51.......................
Unit Start Up 57....................................
Gas Pressure Measurement 58......................
Proper Combustion 59..............................
High Altitude 59....................................
Repair Parts List 60................................
Testing For Sufficient Combustion Air Non-Direct Vent 60
Sequence of Operation 61..........................
Service 63........................................
Program Unit Capacity Size Mode 64.................
Litho U.S.A.
Question and Answer IconNeed help?

Do you have a question about the Lennox EL296UHV and is the answer not in the manual?

Lennox EL296UHV Specifications

General IconGeneral
EfficiencyUp to 96% AFUE
StagesTwo-stage
BlowerVariable-speed
Fuel TypeNatural Gas or Propane
Energy Star CertifiedYes
Heating Capacity44, 000-132, 000 BTU/h
WarrantyLimited lifetime warranty on heat exchanger, 5-year limited warranty on covered components
IgnitionSureLight® Igniter
Filter SizeDepends on installation

Summary

Installation Instructions

EL296UHV Unit Dimensions

Provides physical measurements and specifications for the EL296UHV furnace.

Shipping and Packing List

Details the components included with the furnace shipment.

Safety Information and Warnings

Highlights critical safety precautions and warnings for installation and operation.

Installation Locations and Clearances

Specifies acceptable locations and required clearances for furnace installation.

System Setup and Connections

General Installation Guidelines

Offers general recommendations for furnace placement and installation.

Combustion Air Requirements

Details needs for combustion, dilution, and ventilation air supply.

Confined and Unconfined Spaces

Defines and provides requirements for air supply in confined or unconfined spaces.

Setting Equipment and Airflow

Covers furnace positioning, leveling, and airflow configuration.

Venting and Exhaust Systems

Venting Practices and Guidelines

Outlines essential practices for proper venting system installation.

Vent Pipe Sizing and Lengths

Provides tables and guidance for selecting appropriate vent pipe sizes and lengths.

Intake and Exhaust Piping Details

Illustrates typical intake and exhaust pipe connection configurations.

Vent Termination Clearances

Specifies required clearances for vent terminals in US and Canada.

Utilities and Controls

Condensate Piping and Trap Assembly

Details condensate trap and piping installation for proper drainage.

Gas Piping Installation

Covers gas supply piping requirements, connections, and leak checks.

Electrical System and Wiring

Explains electrical connections, grounding, and wiring precautions.

Thermostat and Control Systems

Discusses thermostat selection, communicating vs. non-communicating, and control logic.

Operation and Performance

Blower Data and Settings

Provides blower performance data and DIP switch settings for various speeds.

Unit Start-Up Procedure

Guides through the initial start-up process, including safety checks and priming.

Proper Combustion and Altitude Effects

Covers combustion analysis and adjustments for high altitude installations.

Service and Compliance

Service and Maintenance

Details procedures for routine checks, cleaning, and basic maintenance.

Program Unit Capacity/Size Mode

Explains how to configure the furnace control for its specific model and capacity.

Regulatory Compliance

Outlines specific installation requirements for Massachusetts and Ontario.