BLOWER DATA
EL296DF110XV60C BLOWER PERFORMANCE (less lter)
BOTTOM RETURN AIR
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
HEATING
1
Heating Speed
DIP Switch
Settings
First Stage Heating Speed - cfm Second Stage Heating Speed - cfm
+24% 1535 2015
+18% 1445 1935
+12% 1370 1855
+6% 1300 1760
Factory Default 1220 1645
–6% 1135 1545
–12% 1070 1420
–18% 1000 1335
COOLING
1
Cooling Speed
DIP Switch
Settings
First Stage Cooling Speed - cfm Second Stage Cooling Speed - cfm
Low Medium-Low Medium-High
2
High Low Medium-Low Medium-High
2
High
+ 1095 1265 1395 1585 1585 1790 1990 2180
Factory Default 965 1130 1285 1440 1440 1630 1845 2005
860 1035 1130 1275 1275 1475 1655 1845
1
Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specic
DIP Switch Settings.
2
Factory default setting.
NOTES - The e󰀨ect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT.
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is selectable at 28% and 38% of the selected second stage cooling speed - minimum 450 cfm.
Lennox iHarmony
®
Zoning System Applications - Minimum blower speed is 450 cfm.
TABLE 22
Allowable Heating Speeds
EL296DFV
Model
-18% -12% -6% Default +6% +12% +18% +24%
All Models Allowed Allowed Allowed
Factory
Setting
Allowed Allowed Allowed Allowed
TABLE 23
Allowable Circulation Speeds
EL296DFV Model Number
28%
(second stage cool)
38%
(second stage cool)
All Models Allowed Factory Setting