7
FWCK/FWHK 08 -Nominal air flow 1900 m
3
/h
FWCK/FWHK 10 -Nominal air flow 2000 m
3
/h
FWCK/FWHK 12 -Nominal air flow 2500 m
3
/h
Nominal capacity conditions: Exchanger air inlet temperature:: 27ºC DB/19ºC WB for cooling y 20ºC WB for heating mode.
For another working conditions use correction factor tables.
9,19
9,36
9,55
9,50
9,67
9,84
10,23
10,40
10,57
10,86
11,04
11,25
11,32
11,49
11,71
-----
-----
-----
-----
-----
-----
-----
-----
-----
1204
1505
1806
1204
1505
1806
1204
1505
1806
1204
1505
1806
1204
1505
1806
-----
1505
1806
Minimum
Nominal
Maximum
Minimum
Nominal
Maximum
Minimum
Nominal
Maximum
Minimum
Nominal
Maximum
Minimum
Nominal
Maximum
Minimum
Nominal
Maximum
Minimum
Nominal
Maximum
-----
-----
-----
51
83
124
51
83
124
51
83
124
51
83
124
51
83
124
-----
83
124
-----
-----
-----
10,34
10,39
10,44
9,82
9,87
9,92
9,13
9,18
9,23
8,35
8,40
8,45
7,57
7,62
7,67
-----
6,93
6,98
-----
-----
-----
7,17
7,18
7,22
7,03
7,06
7,08
6,79
6,81
6,84
6,55
6,57
6,59
6,30
6,33
6,35
-----
6,04
6,05
-----
-----
-----
1,95
1,92
1,88
2,11
2,07
2,03
2,28
2,23
2,18
2,44
2,38
2,33
2,59
2,53
2,48
-----
2,70
2,64
2,60
2,63
2,66
2,64
2,66
2,68
2,72
2,75
2,78
2,79
2,82
2,86
2,84
2,87
2,91
-----
-----
-----
-----
-----
-----
Water inlet
temperature ºC
Water flow
l/h
Water pressure
drop
kPa
COOLING CAPACITY FWCK/FWHK HEATING CAPACITY FWHK
Total capacity
kW
Sensible capacity
kW
Total power input
kW
Total capacity
kW
Total power input
kW
12°C
15ºC
20ºC
25ºC
30ºC
35ºC
40ºC
10,87
11,07
11,30
11,24
11,44
11,63
12,10
12,30
12,50
12,85
13,06
13,30
13,39
13,59
13,84
-----
-----
-----
-----
-----
-----
-----
-----
-----
1463
1829
2195
1463
1829
2195
1463
1829
2195
1463
1829
2195
1463
1829
2195
-----
1829
2195
Minimum
Nominal
Maximum
Minimum
Nominal
Maximum
Minimum
Nominal
Maximum
Minimum
Nominal
Maximum
Minimum
Nominal
Maximum
Minimum
Nominal
Maximum
Minimum
Nominal
Maximum
-----
-----
-----
29
45
66
29
45
66
29
45
66
29
45
66
29
45
66
-----
45
66
-----
-----
-----
12,55
12,62
12,68
11,92
11,99
12,05
11,08
11,15
11,21
10,14
10,20
10,26
9,19
9,25
9,32
-----
8,41
8,48
-----
-----
-----
8,65
8,66
8,71
8,48
8,51
8,54
8,19
8,22
8,25
7,89
7,92
7,95
7,59
7,62
7,65
-----
7,28
7,29
-----
-----
-----
2,24
2,20
2,16
2,42
2,38
2,33
2,61
2,55
2,50
2,79
2,73
2,67
2,97
2,91
2,85
-----
3,09
3,02
2,97
3,01
3,05
3,02
3,05
3,08
3,12
3,15
3,19
3,20
3,23
3,27
3,25
3,29
3,33
-----
-----
-----
-----
-----
-----
Water inlet
temperature ºC
Water flow
l/h
Water pressure
drop
kPa
COOLING CAPACITY FWCK/FWHK HEATING CAPACITY FWHK
Total capacity
kW
Sensible capacity
kW
Total power input
kW
Total capacity
kW
Total power input
kW
12°C
15ºC
20ºC
25ºC
30ºC
35ºC
40ºC
13,25
13,50
13,78
13,71
13,95
14,19
14,76
15,00
15,24
15,67
15,92
16,22
16,32
16,58
16,88
-----
-----
-----
-----
-----
-----
-----
-----
-----
1872
2340
2808
1872
2340
2808
1872
2340
2808
1872
2340
2808
1872
2340
2808
-----
2340
2808
Minimum
Nominal
Maximum
Minimum
Nominal
Maximum
Minimum
Nominal
Maximum
Minimum
Nominal
Maximum
Minimum
Nominal
Maximum
Minimum
Nominal
Maximum
Minimum
Nominal
Maximum
-----
-----
-----
48
75
108
48
75
108
48
75
108
48
75
108
48
75
108
-----
75
108
-----
-----
-----
16,00
16,08
16,16
15,20
15,28
15,36
14,12
14,21
14,29
12,92
13,00
13,08
11,71
11,79
11,88
-----
10,72
10,80
-----
-----
-----
11,10
11,12
11,18
10,89
10,93
10,97
10,51
10,55
10,59
10,13
10,17
10,21
9,75
9,79
9,83
-----
9,35
9,36
-----
-----
-----
2,85
2,80
2,74
3,08
3,02
2,96
3,32
3,25
3,18
3,55
3,47
3,39
3,78
3,69
3,62
-----
3,93
3,84
3,70
3,74
3,79
3,76
3,79
3,83
3,88
3,92
3,97
3,98
4,02
4,07
4,05
4,09
4,15
-----
-----
-----
-----
-----
-----
Water inlet
temperature ºC
Water flow
l/h
Water pressure
drop
kPa
COOLING CAPACITY FWCK/FWHK HEATING CAPACITY FWHK
Total capacity
kW
Sensible capacity
kW
Total power input
kW
Total capacity
kW
Total power input
kW
12°C
15ºC
20ºC
25ºC
30ºC
35ºC
40ºC
DB.- Dry bulb.
WB.- Wet bulb.