ELECTRICAL DATA
Line Voltage Data  60Hz. - 1ph
Model No.
Compressor
Condenser
Fan Motor
Evaporator
Blower
Recommended Max. Fuse Size (amps)
Unit Power Factor
Rated Load Amps
Locked Rotor Amps
Full Load Amps
Locked Rotor Amps
Full Load Amps
Locked Rotor Amps
GCS16H261 GCS16H311
GCS16R411
GCS16413
GCS16R511
GCS16513
GCS16R651
GCS16653
Line Voltage Data  60Hz. - 3ph
Model No.
Compressor
Condenser
Fan Motor
Evaporator
Blower
Recommended Max. Fuse Size (amps)
Unit Power Factor
Rated Load Amps
Locked Rotor Amps
Full Load Amps
Locked Rotor Amps
Full Load Amps
Locked Rotor Amps
ELECTRICAL DATA
Combustion Air Blower - FLA
Combustion Air Blower - FLA
208/230v 208/230v 208/230v 208/230v 208/230v
208/230v 208/230v 208/230v460v 460v 460v575v 575v
12.0 13.5 17.6 23.5 27.6
57.0 77.4 87.0 118.0 135.0
1.4 1.4 1.1
2.0
2.0
2.9 2.9 1.9 4.4 4.4
2.2 2.2 3.9 4.6 4.6
4.6 4.6 8.3 10.0 10.0
0.75 0.75 0.75 0.60 0.60
30 30 45 60 60
19.0 20.0 27.0 36.0 42.0
11.5 5.3 15.4 8.4 6.4 17.6 9.4 8.4
70 35 90 45 43 105 55
50
1.1 0.75 2.0 1.1 1.8 2.0 1.1 1.8
1.9 1.3 4.4 2.2 2.2 4.4 2.2 2.2
3.9 1.8 4.6 1.8
0.7
4.6 1.8 0.7
8.3 4.4 10.0 3.8 3.8
10.0
3.8 3.8
0.75 0.75 0.60 0.60 0.60 0.60 0.60 0.60
30 15 40 20 15 45 25 20
.86 .86 .84 .87 .87 .86 .88 .88
Where current does not exceed 60 amps, HACR circuit breaker may be used in place of fuse.
NOTE - Extremes of operating range are plus and minus 10% of line voltage.
*Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.
GCS16411 GCS16511 GCS16651
0.75 in GCS16-650-75 and GCS16R-651-75.
*Minimum Circuit Ampacity
.96 .95 .95 .93 .95
*Minimum Circuit Ampacity
20.0 10.0 26.0 14.0 11.0 29.0 15.0 13.0
ACCESSORY AIR RESISTANCE
Unit
Model
No.
Air
Volume
(cfm)
REMD16
Economizer
Downflow
Total Resistance (inches water gauge)
EMDH16
Economizer
Downflow
RDE16-41
Duct
Enclosure
Downflow
Filter
Adaptor
Kit
RTD9-65 Diffuser
2 Ends
Open
1 Side
2 Ends
Open
All Ends
& Sides
Open
FD9-65
Diffuser
GCS16H-261
GCS16H-311
800
1000
1200
GCS16-410
800
1000
1200
1400
GCS16-510
GCS16-650
1600
1800
2000
2200
.16
.20
.24
.16
.20
.24
.28
.16
.19
.23
.27
---
---
---
.18
.20
.35
.50
.30
.35
.40
.47
.11
.19
.22
---
---
---
---
---
---
---
---
---
---
---
.15
.18
.21
.25
.15
.17
.20
.23
.15
.19
.25
.15
.19
.25
.33
.43
.56
.73
.95
.13
.16
.20
.13
.16
.20
.26
.32
.40
.50
.63
.11
.14
.17
.11
.14
.17
.20
.24
.30
.36
.44
.11
.14
.17
.11
.14
.17
.20
.24
.30
.36
.44
With
Filter
Without
Filter
With
Filter
Without
Filter
.01
.02
.03
.01
.02
.03
.03
.01
.02
.03
.04
---
---
---
.01
.02
.03
.03
.01
.02
.03
.04
Air resistance is with air filter in place.