Service Literature
Revised 04−2004
HS29 SERIES UNITS
The HS29 is a residential split-system condensing unit.
Condensing coil size, circuiting and air volume result in a
minimum SEER rating of 10.0. The series is designed for
use with an expansion valve or RFCIV system in the in-
door unit. However, the HS29−651 and060 use only the
TXV system.
The HS29−141 and −012 utilizes a rotary compressor. Other
HS29 units (−018, 024−2 and −211 through −653) utilize a recip-
rocating compressor. All compressors are hermetically sealed
for trouble-free operation and long service life. Compressor
components are spring-mounted within the sealed housing.
The compressor is installed in the unit on resilient rubber
mounts to assure quiet, vibration-free operation. A built-in
protection device assures protection from excessive
current and temperatures.
HS29−460 through HS29−650 models are furnished with
crankcase heaters to assure proper compressor lubrica-
tion at all times. The heater is temperature-actuated and
operates only when required. HS29024−3 and HS29−030
through −060 units utilize a scroll compressor. The scroll oper-
ates like a standard compressor but it is unique in the way it
compresses refrigerant.
Several models are available in sizes ranging from 1 through 5
tons.
WARNING
Refrigerant can be harmful if it is inhaled. Refrigerant
must be used and recovered responsibly.
Failure to follow this warning may result in personal
injury or death.
IMPORTANT
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, person-
al injury or loss of life. Installation and service must
be performed by a qualified installer or service
agency.
This manual is divided into sections which discuss the
major components, refrigerant system, charging proce-
dure, maintenance and operation sequence.
All specifications in this manual are subject to change.
TABLE OF CONTENTS
Specifications 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Data 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I Unit Information 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
II Unit Components 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
III Refrigerant System 8. . . . . . . . . . . . . . . . . . . . . . . . . .
IV Charging 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V Maintenance 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VI Wiring Diagrams and Operation Sequence 15. . . . . .
Question and Answer IconNeed help?

Do you have a question about the Lennox HS29-211 and is the answer not in the manual?

Lennox HS29-211 Specifications

General IconGeneral
ModelHS29-211
TypeHeat Pump
RefrigerantR-410A
Voltage208/230V
Phase1

Summary

I - Unit Information

II - Unit Components

Control Box Components

Details electrical components in the control box, including contactors, capacitors, relays, and transformers.

Compressor Types

Describes the different compressor types used in the HS29 series: rotary, reciprocating, and scroll.

III - Refrigerant System

Plumbing

Details field refrigerant piping, line sets, and service port connections for the system.

IV - Charging

Pumping Down System

Procedure for pumping down the system for leak checking or repairs.

Leak Testing

Steps for performing leak tests on the line set and indoor coil using nitrogen.

Evacuating the System

Guidelines for evacuating the system to achieve a deep vacuum.

Charging Methods

Procedures for charging the system using expansion valve or RFCIV methods.

Oil Charge

Information on checking and maintaining the compressor oil charge.

V - Maintenance

Outdoor Unit Maintenance

Instructions for cleaning and inspecting the outdoor unit's condenser coil and lines.

Indoor Coil Maintenance

Guidance on cleaning the indoor coil and checking connecting lines.

Indoor Unit Checks

Checks for indoor units including filters, bearings, wiring, voltage, and amp-draw.

VI - Wiring Diagrams and Sequence of Operation

HS29-1 Single-Phase Operating Sequence (Reciprocating or Rotary)

Details the cooling cycle operation for HS29 single-phase units with reciprocating or rotary compressors.

HS29-2 & -3 Single-Phase Operating Sequence (Reciprocating or Rotary)

Outlines the cooling cycle for HS29 single-phase units, models -2 and -3, with reciprocating or rotary compressors.

HS29 Three-Phase Operating Sequence

Details the cooling cycle operation for HS29 three-phase units.

HS29-1 Single-Phase Operating Sequence (Scroll Compressors)

Details the cooling cycle operation for HS29 single-phase units with scroll compressors.

HS29-2 & -3 Single-Phase Operating Sequence (Scroll Compressors)

Details the cooling cycle operation for HS29 single-phase units, models -2 and -3, with scroll compressors.

Related product manuals