EasyManua.ls Logo

Lennox HS29-683 User Manual

Lennox HS29-683
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Page 1
©1998 Lennox Industries Inc.
Corp. 9802−L3
HS29
Service Literature
Revised 04−2004
HS29 SERIES UNITS
The HS29 is a residential split-system condensing unit.
Condensing coil size, circuiting and air volume result in a
minimum SEER rating of 10.0. The series is designed for
use with an expansion valve or RFCIV system in the in-
door unit. However, the HS29−651 and060 use only the
TXV system.
The HS29−141 and −012 utilizes a rotary compressor. Other
HS29 units (−018, 024−2 and −211 through −653) utilize a recip-
rocating compressor. All compressors are hermetically sealed
for trouble-free operation and long service life. Compressor
components are spring-mounted within the sealed housing.
The compressor is installed in the unit on resilient rubber
mounts to assure quiet, vibration-free operation. A built-in
protection device assures protection from excessive
current and temperatures.
HS29−460 through HS29−650 models are furnished with
crankcase heaters to assure proper compressor lubrica-
tion at all times. The heater is temperature-actuated and
operates only when required. HS29024−3 and HS29−030
through −060 units utilize a scroll compressor. The scroll oper-
ates like a standard compressor but it is unique in the way it
compresses refrigerant.
Several models are available in sizes ranging from 1 through 5
tons.
WARNING
Refrigerant can be harmful if it is inhaled. Refrigerant
must be used and recovered responsibly.
Failure to follow this warning may result in personal
injury or death.
IMPORTANT
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, person-
al injury or loss of life. Installation and service must
be performed by a qualified installer or service
agency.
This manual is divided into sections which discuss the
major components, refrigerant system, charging proce-
dure, maintenance and operation sequence.
All specifications in this manual are subject to change.
TABLE OF CONTENTS
Specifications 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Data 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I Unit Information 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
II Unit Components 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
III Refrigerant System 8. . . . . . . . . . . . . . . . . . . . . . . . . .
IV Charging 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V Maintenance 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VI Wiring Diagrams and Operation Sequence 15. . . . . .
Question and Answer IconNeed help?

Do you have a question about the Lennox HS29-683 and is the answer not in the manual?

Lennox HS29-683 Specifications

General IconGeneral
BrandLennox
ModelHS29-683
CategoryHeat Pump
LanguageEnglish

Summary

IV - CHARGING

C - Evacuating the System

Detailed steps for evacuating the system to the required vacuum level.

D - Charging Methods

Procedures for charging expansion valve and RFCIV systems, including temperature and pressure guidelines.

VI - WIRING DIAGRAMS AND SEQUENCE OF OPERATION

HS29-1 Single-Phase Sequence

Describes the cooling sequence of operation for single-phase units with reciprocating or rotary compressors.

HS29-2 & -3 Single-Phase Sequence

Details the cooling sequence for single-phase units (reciprocating/rotary compressors).

HS29 Three-Phase Sequence

Explains the cooling sequence for three-phase units with all compressor types.

HS29-1 Single-Phase Sequence (Scroll Compressors)

Outlines the cooling sequence for single-phase units using scroll compressors.

Related product manuals