Do you have a question about the Lennox LCH120H and is the answer not in the manual?
Brand | Lennox |
---|---|
Model | LCH120H |
Category | Air Conditioner |
Language | English |
Overview of LCH092 through 152U units, featuring factory options and cooling capacities.
Information on blower options, motors, and drive kits for supply air.
Options for blower proving switches, commercial controls, and filter switches.
Electric heat options available in various kW sizes and voltage configurations.
Standard and high-performance economizer options and their controls.
General data including tonnage, model, efficiency, and blower type.
Cooling capacity, airflow, power, and efficiency ratings.
Refrigerant types and charge amounts for different coil systems.
Available electric heat capacities in kW.
Details on outdoor coil face area, rows, and fins per inch.
Specifications for outdoor coil fan motors, RPM, and watts.
Specifications for indoor coil face area, tube diameter, rows, and fins per inch.
Details on blower drive selection, motor output, and drive kit numbers.
General data for 10 and 12.5 ton units.
Cooling performance data for 10 and 12.5 ton units.
Refrigerant charge for 10 and 12.5 ton units.
Available electric heat kW for 10 and 12.5 ton units.
Outdoor coil specifications for 10 and 12.5 ton units.
Outdoor coil fan specs for 10 and 12.5 ton units.
Indoor coil specifications for 10 and 12.5 ton units.
Blower and drive selection for 10 and 12.5 ton units.
Supply air blower options for models 094, 122, 152.
Control options for models 094, 122, 152.
Direct drive electric heat options by kW and voltage.
Belt drive electric heat options by kW and voltage.
Economizer options and controls for models 094, 122, 152.
General data for direct drive models.
Cooling performance specs for direct drive models.
Refrigerant charge for direct drive models.
Available electric heat kW for direct drive models.
Outdoor coil specifications for direct drive models.
Outdoor coil fan specifications for direct drive models.
Indoor coil specifications for direct drive models.
Indoor blower specifications for direct drive models.
General data for belt drive models.
Cooling performance specs for belt drive models.
Blower and drive selection for belt drive models.
Minimum air volume requirements for optional electric heat.
Minimum air volume for electric heat with belt drive.
Minimum air volume for electric heat with belt drive.
Electrical and heat data for 7.5 ton high efficiency units.
Electric heat capacities and protection ratings.
Electrical and heat data for 8.5 ton high efficiency units.
Electric heat capacities and protection for 8.5 ton units.
Electrical and heat data for 10 ton high efficiency units.
Electric heat capacities and protection for 10 ton units.
Electrical and heat data for 12.5 ton high efficiency units.
Electric heat capacities and protection for 12.5 ton units.
Electrical and heat data for 7.5 ton direct drive models.
Electric heat capacities and protection for 7.5 ton direct drive.
Electrical and heat data for 10 ton direct drive models.
Electric heat capacities and protection for 10 ton direct drive.
Electrical and heat data for 12.5 ton direct drive models.
Electric heat capacities and protection for 12.5 ton direct drive.
Electrical and heat data for 7.5 ton belt drive models.
Electric heat capacities and protection for 7.5 ton belt drive.
Electrical and heat data for 10 ton belt drive models.
Electric heat capacities and protection for 10 ton belt drive.
Electrical and heat data for 12.5 ton belt drive models.
Electric heat capacities and protection for 12.5 ton belt drive.
Diagram showing component layout for specific LCH models.
Diagram showing component layout for specific LCH models.
Functionality and features of the A55 Unit Controller.
Diagram of refrigerant circuits for standard efficiency fin tube coils.
Diagram of refrigerant circuits for high efficiency all-aluminum coils.
Diagram of refrigerant circuits for ultra high efficiency units.
Procedure to measure and adjust unit air volume.
Table of min/max CFM for specific unit models.
Wiring diagram for constant supply air, belt drive units.
Sequence for initiating first stage cooling.
Sequence for initiating second stage cooling.
First stage cooling sequence for staged units.
Second stage cooling sequence for staged units.
Troubleshooting steps for blower failures and alarms.
Fault sequence for direct drive motor without S52 switch.
Fault sequence for direct drive motor with S52 switch.
Troubleshooting steps for direct drive blower failures.
Wiring diagram for electric heat configurations.
Electric heat sequence for G, J, M voltage units.
Electric heat sequence for Y voltage units.