ELECTRICAL/ELECTRIC HEAT DATA 20 TON
Model No. LHT240H4
1
Voltage - 60Hz 208/230V - 3 Ph 460V - 3 Ph 575V - 3 Ph
Compressor 1
(Non-Inverter)
Rated Load Amps   11.1
Locked Rotor Amps 240 130 93.7
Compressor 2
(Non-Inverter)
Rated Load Amps 31.1 13 11
Locked Rotor Amps 255 123 93.7
Outdoor Fan

 2.4 1.3 1
Total 14.4 

(2) 0.33 HP
Full Load Amps 2.4 1.3 1
Total   2
Service Outlet 115V GFI (amps) 15 15 20
Indoor Blower
Motor
Horsepower 5 7.5 10 5 7.5 10 5 7.5 10
Full Load Amps  24.2   11 14  9 11
2

Overcurrent
Protection (MOCP)
Unit Only 125 125 125    45 50 50
With (2) 0.33 HP

125 125 150   70 50 50 50
3
Minimum
Circuit
Ampacity (MCA)
Unit Only 103 111  47 51 54 37 40 42
With (2) 0.33 HP

  122 50 53  39 42 44
ELECTRIC HEAT DATA
Electric Heat Voltage 208V 240V 208V 240V 208V 240V 480V 480V 480V 600V 600V 600V
2

Overcurrent
Protection (MOCP)
Unit+
Electric Heat
15 kW 150 150
4
150 175 175 175 70     
30 kW 200 200
4
200 225
4
200 225 100 100 100   
45 kW
4
225 250 250 250
4
250
4
300 125 125 125 100 100 100
60 kW 250 250
4
250
4
300
4
250
4
300 125 125 150 100 100 110
90 kW
4
300
4
350
4
300
4
350 350
4
350 175 175 175 125 150 150
3
Minimum
Circuit
Ampacity (MCA)
Unit+
Electric Heat
15 kW 143 149 150  157  70 73    
30 kW  194  201   93  99 74  
45 kW 221 239   235 253 115  121 92 95 97
60 kW 229   255 243  120 123  95  100
90 kW 291 320 299 327 305 334  159  124 127 129
2

Overcurrent
Protection (MOCP)
Unit+
Electric Heat
and (2) 0.33 HP

15 kW
4
150 175 175 175 175 175      70
30 kW 200 200
4
200 225 225 225 100 100 110   
45 kW 250 250
4
250
4
300
4
250
4
300 125 125 125 100 100 100
60 kW
4
250
4
300
4
250
4
300
4
250
4
300 125 150 150 100 110 110
90 kW
4
300
4
350 350
4
350 350
4
350 175 175 175 150 150 150
3
Minimum
Circuit
Ampacity (MCA)
Unit+
Electric Heat
and (2) 0.33 HP

15 kW 147 153 155    73  79   
30 kW   194  201 213 95 99 102   
45 kW  244 233 251 240   121 124 94 97 99
60 kW 233 253 241  247  122  129 97 100 102
90 kW  325 303 332 310 339     129 131
NOTE - All units have a minimum Short Circuit Current Rating (SCCR) of 5000 amps.
1

2
HACR type breaker or fuse.
3

4
Factory installed circuit breaker not available.

Other manuals for Lennox LHT Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox LHT Series and is the answer not in the manual?

Lennox LHT Series Specifications

General IconGeneral
BrandLennox
ModelLHT Series
CategoryHeat Pump
LanguageEnglish

Related product manuals