UNIT INFORMATIONUNIT INFORMATION
Service Literature
8.8.8.8
WARNING
To prevent serious injury or death:
1- Lock-out/tag-out before performing maintenance.
2- If system power is required (e.g., smoke detector
maintenance), disable power to blower, remove
fan belt where applicable, and ensure all
controllers and thermostats are set to the “OFF”
position before performing maintenance.
3- Always keep hands, hair, clothing, jewelry, tools,
etc., away from moving parts.
Table of Contents
Options / Accessories . . . . . . . . . . . . . . . . . . . . . Page 2

Blower Data .. . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7
Electrical / Electric Heat Data.. . . . . . . . . . . . . . . Page 10
Unit Parts Arrangement . . . . . . . . . . . . . . . . . . . Page 14
I-Unit Components . . . . . . . . . . . . . . . . . . . . . . . Page 14
II-Placement and Installation . . . . . . . . . . . . . . . Page 29
III-Charging. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 29
IV Start Up - Operation . . . . . . . . . . . . . . . . . . . . Page 31
V-System Service Checks . . . . . . . . . . . . . . . . . Page 31
VI-Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . Page 31
VII-Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . Page 32

IX-Wiring and Operation Sequence . . . . . . . . . . Page 39
        
(CTO) with a wide selection of factory installed options.

heat operates in single or multiple stages depending on
-

heat sections are available for the LHT240.


Multi-Stage Air Volume MSAV
®
blower option is available.
The VFD-driven blower will operate at lower speeds when
demand is low and increase to higher speeds when de-
mand is high.
󰀨-
ent energy management thermostat control systems with
-
tions connect to the unit through Smartwire connectors.
When “plugged in” the controls become an integral part of
the unit wiring.
The CORE Control System is designed to accelerate
equipment install and service. Standard with all Enlight

   󰀩
protect your investments.
The CORE Unit Controller is a microprocessor-based

Information contained in this manual is intended for use

subject to change. Procedures outlined in this manual are
presented as a recommendation only and do not super-
sede or replace local or state codes.

four cables to the holes located in the unit base rail (two
holes at each corner). Refer to the installation instructions
for the proper rigging technique.
WARNING
Improper installation, adjustment, alteration,
service or maintenance can cause property damage,
personal injury or loss of life. Installation and service
must be performed by a licensed professional HVAC
installer or equivalent, service agency, or the gas
supplier
LHT SERIES
13 to 20 ton

LHT156 through 240

Other manuals for Lennox LHT180

Question and Answer IconNeed help?

Do you have a question about the Lennox LHT180 and is the answer not in the manual?

Lennox LHT180 Specifications

General IconGeneral
SEERUp to 18
RefrigerantR-410A
Cooling Capacity (BTU/h)18000-60000
Sound Level (Outdoor Unit, dB)59
Operating Temperature Range (Heating)-15°F to 115°F

Summary

SPECIFICATIONS

General Unit Specifications

Provides overall unit data, performance, and electrical characteristics.

Cooling and Heating Performance Specs

Details cooling and heating performance metrics and capacities.

BLOWER DATA

ELECTRICAL/ELECTRIC HEAT DATA

Voltage and Component Electrical Data

Details electrical data for compressors, fans, motors, and service outlets.

Electric Heat Electrical Data

Provides MOCP and MCA for electric heat stages across voltages.

15 Ton Electrical/Electric Heat Data

Specific electrical and electric heat data for the 15-ton model.

20 Ton Electrical/Electric Heat Data

Specific electrical and electric heat data for the 20-ton model.

ELECTRIC HEAT CAPACITIES

PARTS ARRANGEMENT

II-PLACEMENT AND INSTALLATION

III-CHARGING

Refrigerant Charge and Check Procedures

Details procedures for checking and adjusting refrigerant charge using approach method.

IV- START-UP OPERATION

Cooling and Heating Start-up Procedures

Outlines steps for initiating cooling and heating demands and compressor operation.

VIII-Multi-Staged Blower

IX-Wiring Diagrams and Sequence of Operation

Thermostat Wiring Diagram

Provides a wiring diagram for thermostat connections to the control board.

Electric Heat Wiring Diagram

Illustrates wiring for electric heat sections, limits, fuses, and contactors.