1
MINI-SPLIT SYSTEMS SERVICE MANUAL
Indoor and Outdoor Unit Information
100029
5/2022
Table of Contents
Indoor Unit Information ...................................3
1. M22A and M33C Cassette Non-Ducted Indoor Units ............... 3
1.1. ModelNumberIdentication ........................................................3
1.2. M22AIndoorUnitSpecications ..................................................3
1.3. M33CIndoorUnitSpecications .................................................4
1.4. M22AIndoorUnitDimensions .....................................................5
1.5. M33CIndoorUnitDimensions .....................................................6
1.6. M22AandM33CIndoorUnitClearances ....................................7
1.7. M22AandM33CIndoorUnitControlBoardSwitches
Location .......................................................................................8
1.8. M22AandM33CCondensateDrainTestProcedure ...................9
2. MMDB Ducted Indoor Units ......................................................10
2.1. MMDBModelNumberIdentication ..........................................10
2.2. MMDBIndoorUnitSpecications .............................................. 11
2.3. IndoorUnitBlowerData ............................................................12
2.4. MMDBIndoorUnitDimensions .................................................18
2.5. MMDBIndoorUnitClearances ..................................................19
2.6. CondensatePumpLift-MMDBandM22A/M33C .....................20
2.7. MMDBCondensateDrainTestProcedure.................................20
2.8. MMDBIndoorUnitGravityDrain ...............................................21
3. MWMC and 3WMC-036 Wall Mounted Indoor Units ............... 22
3.1. ModelNumberIdentication ......................................................22
3.2. IndoorUnitSpecications(009-012Ton)Units ......................23
3.3. IndoorUnitSpecications(018-030Ton)Units .......................23
3.4. IndoorUnitSpecications(3WMC) ...........................................23
3.5. IndoorUnitDimensions(MWMCand3WMC) ...........................24
3.6. IndoorUnitClearances(AllModelsandSizes) .........................25
3.7. MWMCand3WMC036S4UnitControlBoardSwitches
Location .....................................................................................25
3.8. DryModeOperation-MWMCand3WMC ................................26
3.9. TestRun-MWMCand3WMC ..................................................26
3.10. Double-CheckPipeConnections ...............................................26
3.11. AmbientTemperatureisBelow63°F(17°C) .............................27
4. MCFA and MCFB Ceiling / Floor Indoor Units ........................28
4.1. ModelNumberIdentication ......................................................28
4.2. IndoorUnitSpecications(018-048Ton)Units .......................28
4.3. IndoorUnitDimensions .............................................................29
4.4. IndoorUnitClearances ..............................................................30
4.5. MCFAandMCFBIndoorUnitControlBoardSwitches
Location .....................................................................................31
5. MFMA Floor Indoor Unit ...........................................................32
5.1. ModelNumberIdentication ......................................................32
5.2. IndoorUnitSpecications(012Ton)Unit ..................................32
5.3. IndoorUnitDimensions .............................................................33
5.4. IndoorUnitClearances ..............................................................33
6. Indoor and Outdoor Power and Communication
Wiring Requirements ............................................................... 34
6.1. Overview ....................................................................................34
6.2. WiringGuide ..............................................................................35
MCFA and MCFB
M22A and M33C
MMDB
MWMC and 3WMC036
MPC, 3PC, and MLB
Single Zone
MLB and MPC
Multi-Zone
MFMA
Please refer to service manual 100030 for indoor and
outdoor unit error codes and component diagnostics.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Lennox MPC030S4S and is the answer not in the manual?

Lennox MPC030S4S Specifications

General IconGeneral
ModelMPC030S4S
Cooling Capacity30, 000 BTU/h
RefrigerantR-410A
Voltage208/230 V
Phase1
Compressor TypeScroll
Refrigerant TypeR-410A
Sound Level (Outdoor Unit)72 dB

Summary

Indoor Unit Information

M22A and M33C Cassette Non-Ducted Units

Specs, dimensions, clearances, and control board for M22A/M33C cassette units.

MMDB Ducted Indoor Units

Specs, dimensions, clearances, and drain procedures for MMDB ducted units.

MWMC and 3WMC-036 Wall Mounted Units

Specs, dimensions, clearances, controls, dry mode, and test run for MWMC/3WMC units.

Wired and Wireless Remotes

Remote Controller Models

Wireless and wired controllers for Lennox mini-split indoor units.

Indoor Unit Connections & Control

Centralized Controller Setup

Setting indoor unit addresses for centralized control (VRF only).

Connecting Cables

Power cord connection specs and wire gauge selection.

Outdoor Unit Information

Single and Multiple Zone Outdoor Unit Specs

Model ID and specifications for MPC, 3PC, MLB single/multi-zone outdoor units.

Installation Requirements

Torque, pipe length/elevation, refrigerant charge, leak checks, and air purging.

Pressure on Service Port

Cooling/heating charts, capacity calculations, and fan/valve control logic.

Related product manuals