MINI-SPLIT SYSTEMS SERVICE MANUAL
Indoor and Outdoor Unit Information
100029
5/2022
Table of Contents
Indoor Unit Information ...................................3
1. M22A and M33C Cassette Non-Ducted Indoor Units ............... 3
1.1. ModelNumberIdentication ........................................................3
1.2. M22AIndoorUnitSpecications ..................................................3
1.3. M33CIndoorUnitSpecications .................................................4
1.4. M22AIndoorUnitDimensions .....................................................5
1.5. M33CIndoorUnitDimensions .....................................................6
1.6. M22AandM33CIndoorUnitClearances ....................................7
1.7. M22AandM33CIndoorUnitControlBoardSwitches
Location .......................................................................................8
1.8. M22AandM33CCondensateDrainTestProcedure ...................9
2. MMDB Ducted Indoor Units ......................................................10
2.1. MMDBModelNumberIdentication ..........................................10
2.2. MMDBIndoorUnitSpecications .............................................. 11
2.3. IndoorUnitBlowerData ............................................................12
2.4. MMDBIndoorUnitDimensions .................................................18
2.5. MMDBIndoorUnitClearances ..................................................19
2.6. CondensatePumpLift-MMDBandM22A/M33C .....................20
2.7. MMDBCondensateDrainTestProcedure.................................20
2.8. MMDBIndoorUnitGravityDrain ...............................................21
3. MWMC and 3WMC-036 Wall Mounted Indoor Units ............... 22
3.1. ModelNumberIdentication ......................................................22
3.2. IndoorUnitSpecications(009-012Ton)Units ......................23
3.3. IndoorUnitSpecications(018-030Ton)Units .......................23
3.4. IndoorUnitSpecications(3WMC) ...........................................23
3.5. IndoorUnitDimensions(MWMCand3WMC) ...........................24
3.6. IndoorUnitClearances(AllModelsandSizes) .........................25
3.7. MWMCand3WMC036S4UnitControlBoardSwitches
Location .....................................................................................25
3.8. DryModeOperation-MWMCand3WMC ................................26
3.9. TestRun-MWMCand3WMC ..................................................26
3.10. Double-CheckPipeConnections ...............................................26
3.11. AmbientTemperatureisBelow63°F(17°C) .............................27
4. MCFA and MCFB Ceiling / Floor Indoor Units ........................28
4.1. ModelNumberIdentication ......................................................28
4.2. IndoorUnitSpecications(018-048Ton)Units .......................28
4.3. IndoorUnitDimensions .............................................................29
4.4. IndoorUnitClearances ..............................................................30
4.5. MCFAandMCFBIndoorUnitControlBoardSwitches
Location .....................................................................................31
5. MFMA Floor Indoor Unit ...........................................................32
5.1. ModelNumberIdentication ......................................................32
5.2. IndoorUnitSpecications(012Ton)Unit ..................................32
5.3. IndoorUnitDimensions .............................................................33
5.4. IndoorUnitClearances ..............................................................33
6. Indoor and Outdoor Power and Communication
Wiring Requirements ............................................................... 34
6.1. Overview ....................................................................................34
6.2. WiringGuide ..............................................................................35
MCFA and MCFB
M22A and M33C
MMDB
MWMC and 3WMC036
MPC, 3PC, and MLB
Single Zone
MLB and MPC
Multi-Zone
MFMA
Please refer to service manual 100030 for indoor and
outdoor unit error codes and component diagnostics.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Lennox MPC and is the answer not in the manual?

Lennox MPC Specifications

General IconGeneral
BrandLennox
ModelMPC
CategoryAir Conditioner
LanguageEnglish

Summary

M22A and M33C Cassette Non-Ducted Indoor Units

M22A Indoor Unit Specifications

Technical specifications for the M22A indoor unit series.

M33C Indoor Unit Specifications

Technical specifications for the M33C indoor unit series.

MMDB Ducted Indoor Units

MMDB Indoor Unit Specifications

Technical specifications for MMDB ducted indoor units.

MWMC and 3WMC-036 Wall Mounted Indoor Units

Indoor Unit Specifications (009 - 012 Ton) Units

Technical specifications for MWMC units (009-012 Ton).

Indoor Unit Specifications (018 - 030 Ton) Units

Technical specifications for MWMC units (018-030 Ton).

Test Run - MWMC and 3WMC

Instructions for performing a test run on MWMC and 3WMC units.

MCFA and MCFB Ceiling / Floor Indoor Units

Indoor Unit Specifications (018 - 048 Ton) Units

Technical specifications for MCFA/MCFB units (018-048 Ton).

MFMA Floor Indoor Unit

Indoor Unit Specifications (012 Ton) Unit

Technical specifications for the MFMA012S4 indoor unit.

Power and Communication Wiring Requirements

Wiring Guide

Table detailing wiring requirements for single-zone mini-split systems.

Multi-Zone Installation Wiring Requirements

Table detailing wiring requirements for multi-zone systems.

Terminal Connections

Diagrams illustrating terminal connections for single and multi-zone systems.

Connection to Centralized Controller, ON/OFF and Alarm Devices

Single and Multiple Zone Outdoor Units

MPC Single-Zone Specifications (0.75 - 1.5 Ton)

Technical specifications for MPC single-zone units (0.75-1.5 Ton).

MPC Single-Zone Specifications (2 - 4 Ton)

Technical specifications for MPC single-zone units (2-4 Ton).

MLB Single-Zone Specifications (0.75 - 2 Ton)

Technical specifications for MLB single-zone units (0.75-2 Ton).

Indoor / Outdoor Unit Combinations

MPC Multi-Zone System Combinations

MPC multi-zone system combinations for cooling and heating capacities.

MLB Multi-Zone System Combinations

MLB multi-zone system combinations for cooling and heating capacities.

Refrigeration Pipe Work

Single-Zone Piping Limitations

Guidelines for single-zone piping length and elevation.

Multi-Zone Piping Limitations

Guidelines for multi-zone piping length and elevation.

Master Valves (3 to 5 Zone Outdoor Units)

MPC Multi-Zone Outdoor Unit Connections and Line Set Usage

MLB Multi-Zone Outdoor Unit Connections and Line Set Usage

Power and Communication Wiring for Systems

Power and Communication Wiring for Systems

Safety precautions and overview for system power and communication wiring.

Outdoor Unit Condensate Piping

MPC Condensate Pump Diagrams

Installation Requirements

Additional Refrigerant Charge

Calculation and guidelines for adding refrigerant based on pipe length.

Evacuation after Servicing the Outdoor Unit Refrigeration Circuit

Evacuation procedure for the complete refrigeration circuit.

Single-Zone Outdoor Unit LED Locations

Multi-Zone Outdoor Unit LEDs and SW1 Locations

Specifications and Operations

Defrost Control

Defrost Theory

Theory behind defrost mode activation and conditions.