INSTALLATION
INSTRUCTIONS
©
2024 Lennox Industries Inc.
Dallas, Texas, USA
WARNING
Improper installation, adjustment, alteration, ser vice or
maintenance can cause property damage, personal
injury or loss of life.
Installation and service must be performed by a li censed
professional HVAC installer (or equivalent) or a service
agency.
WARNING
The clean Air Act of 1990 bans the intentional venting of
refrigerant (CFCs, HCFCs, and HFCs) as of July, 1992.
Approved methods of recovery, recycling or reclaiming
must be followed. Fines and/or incarceration may be
levied for non-compliance.
CAUTION
As with any mechanical equipment, contact with sharp
sheet metal edges can result in personal injury. Take
care while handling this equipment and wear gloves and
protective clothing.
General
These instructions are intended as a general guide and
do not supersede local or national codes in any way.
Authorities having jurisdiction should be consulted before
installation.
The MWMC wall-mounted indoor units are matched with
an outdoor heat pump unit to create a mini-split system
that uses HFC-410A refrigerant.
MLB/MPC Outdoor Units
with MWMC Indoor Units
SINGLE-ZONE MINI-SPLIT SYSTEMS
(115V and 208/230V) --
Wall-Mounted Indoor Unit
507545-07 04/2024
Supersedes 02/2024
Table of Contents
General .....................................................................................1
Included Parts...........................................................................2
Model Number Identication .....................................................3
Indoor / Outdoor Unit Match-Ups..............................................4
System Dimensions ..................................................................5
Outdoor Units ................................................................................................... 5
Indoor Units ...................................................................................................... 8
Wall Mounting Plates ........................................................................................ 9
System Clearances ................................................................11
Outdoor Unit ................................................................................................... 11
Indoor Unit ...................................................................................................... 11
Torque Requirements for Caps and Fasteners.......................12
Indoor Unit Installation ............................................................12
Unit Placement Considerations ...................................................................... 12
Determining Wall Mounting Plate Location .................................................... 12
Installation of Wall Mounting Plate ................................................................. 13
Installation of Wall Sleeve .............................................................................. 13
Installation of Indoor Unit on Wall Mounting Plate .......................................... 13
Indoor Unit Condensate Piping Connections ................................................. 14
Outdoor Unit Installation .........................................................14
Placement Considerations ............................................................................. 14
Direct Sunlight, Rain, Snow and Ice Protection .............................................. 15
Prevailing Winds ............................................................................................. 16
Buried Refrigerant Pipe Protection ................................................................. 16
Outdoor Unit Condensate Piping .................................................................... 16
Securing the Outdoor Unit .............................................................................. 17
Refrigerant Piping Connections ..............................................17
Leak Test and Evacuation ......................................................19
Leak Test ........................................................................................................ 19
Triple Evacuation Procedure .......................................................................... 20
Wiring Connections ................................................................20
Outdoor Unit .................................................................................................. 20
Indoor Unit ...................................................................................................... 20
Unit Start-Up ...........................................................................28
Adding Refrigerant for Longer Line Set ..................................29
Troubleshooting ......................................................................29
I-Clean Feature.......................................................................30
Test Run .................................................................................31
Pre-Checks ..................................................................................................... 31
Procedure ....................................................................................................... 31
Double-Check Pipe Connections ................................................................... 31
If Ambient Temperature is below 60°F (16°C) ................................................ 31
Dry Mode Operation (Dehumidication) .................................31
Procedure ....................................................................................................... 31
Sequence of Operation .................................................................................. 31
Humidity Control .....................................................................32
Intelligent Eye Function .........................................................32
THIS MANUAL MUST BE LEFT WITH THE OWNER
FOR FUTURE REFERENCE
Question and Answer IconNeed help?

Do you have a question about the Lennox MWMC018S4-2P and is the answer not in the manual?

Lennox MWMC018S4-2P Specifications

General IconGeneral
BrandLennox
ModelMWMC018S4-2P
CategoryIndoor Furnishing
LanguageEnglish

Summary

Model Number Identification

Indoor Outdoor Unit Match-Ups

Indoor Unit Installation

Unit Placement Considerations

Advises on optimal locations for indoor unit installation.

Outdoor Unit Installation

Placement Considerations

Advises on optimal locations for outdoor unit installation.

Direct Sunlight, Rain, Snow and Ice Protection

Recommendations for protecting the outdoor unit from elements.

Securing the Outdoor Unit

Leak Test and Evacuation

Triple Evacuation Procedure

Detailed steps for evacuating the system to remove contaminants.

Wiring Connections

Unit Start-Up

Adding Refrigerant for Longer Line Set

Troubleshooting

Test Run

Dry Mode Operation (Dehumidification)

Instructions for using the unit's dehumidification mode.