EasyManua.ls Logo

Lennox MWMC024S4-2P

Lennox MWMC024S4-2P
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
INSTALLATION
INSTRUCTIONS
©
2024 Lennox Industries Inc.
Dallas, Texas, USA
WARNING
Improper installation, adjustment, alteration, ser vice or
maintenance can cause property damage, personal
injury or loss of life.
Installation and service must be performed by a li censed
professional HVAC installer (or equivalent) or a service
agency.
WARNING
The clean Air Act of 1990 bans the intentional venting of
refrigerant (CFCs, HCFCs, and HFCs) as of July, 1992.
Approved methods of recovery, recycling or reclaiming
must be followed. Fines and/or incarceration may be
levied for non-compliance.
CAUTION
As with any mechanical equipment, contact with sharp
sheet metal edges can result in personal injury. Take
care while handling this equipment and wear gloves and
protective clothing.
General
These instructions are intended as a general guide and
do not supersede local or national codes in any way.
Authorities having jurisdiction should be consulted before
installation.
The MWMC wall-mounted indoor units are matched with
an outdoor heat pump unit to create a mini-split system
that uses HFC-410A refrigerant.
MLB/MPC Outdoor Units
with MWMC Indoor Units
SINGLE-ZONE MINI-SPLIT SYSTEMS
(115V and 208/230V) --
Wall-Mounted Indoor Unit
507545-07 04/2024
Supersedes 02/2024
Table of Contents
General .....................................................................................1
Included Parts...........................................................................2
Model Number Identication .....................................................3
Indoor / Outdoor Unit Match-Ups..............................................4
System Dimensions ..................................................................5
Outdoor Units ................................................................................................... 5
Indoor Units ...................................................................................................... 8
Wall Mounting Plates ........................................................................................ 9
System Clearances ................................................................11
Outdoor Unit ................................................................................................... 11
Indoor Unit ...................................................................................................... 11
Torque Requirements for Caps and Fasteners.......................12
Indoor Unit Installation ............................................................12
Unit Placement Considerations ...................................................................... 12
Determining Wall Mounting Plate Location .................................................... 12
Installation of Wall Mounting Plate ................................................................. 13
Installation of Wall Sleeve .............................................................................. 13
Installation of Indoor Unit on Wall Mounting Plate .......................................... 13
Indoor Unit Condensate Piping Connections ................................................. 14
Outdoor Unit Installation .........................................................14
Placement Considerations ............................................................................. 14
Direct Sunlight, Rain, Snow and Ice Protection .............................................. 15
Prevailing Winds ............................................................................................. 16
Buried Refrigerant Pipe Protection ................................................................. 16
Outdoor Unit Condensate Piping .................................................................... 16
Securing the Outdoor Unit .............................................................................. 17
Refrigerant Piping Connections ..............................................17
Leak Test and Evacuation ......................................................19
Leak Test ........................................................................................................ 19
Triple Evacuation Procedure .......................................................................... 20
Wiring Connections ................................................................20
Outdoor Unit .................................................................................................. 20
Indoor Unit ...................................................................................................... 20
Unit Start-Up ...........................................................................28
Adding Refrigerant for Longer Line Set ..................................29
Troubleshooting ......................................................................29
I-Clean Feature.......................................................................30
Test Run .................................................................................31
Pre-Checks ..................................................................................................... 31
Procedure ....................................................................................................... 31
Double-Check Pipe Connections ................................................................... 31
If Ambient Temperature is below 60°F (16°C) ................................................ 31
Dry Mode Operation (Dehumidication) .................................31
Procedure ....................................................................................................... 31
Sequence of Operation .................................................................................. 31
Humidity Control .....................................................................32
Intelligent Eye Function .........................................................32
THIS MANUAL MUST BE LEFT WITH THE OWNER
FOR FUTURE REFERENCE

Questions and Answers:

Lennox MWMC024S4-2P Specifications

General IconGeneral
BrandLennox
ModelMWMC024S4-2P
CategoryIndoor Furnishing
LanguageEnglish

Summary

Indoor Outdoor Unit Match-Ups

Wall Mounting Plates

System Clearances

Torque Requirements for Caps and Fasteners

Indoor Unit Installation

Installation of Wall Mounting Plate

Steps for correctly positioning and securing the indoor unit's wall plate.

Installation of Indoor Unit on Wall Mounting Plate

Guides on attaching the indoor unit to the wall mounting plate.

Indoor Unit Condensate Piping Connections

Outdoor Unit Installation

Direct Sunlight, Rain, Snow and Ice Protection

Buried Refrigerant Pipe Protection

Outdoor Unit Condensate Piping

Securing the Outdoor Unit

Leak Test and Evacuation

Leak Test

Procedure for testing the system for refrigerant leaks.

Triple Evacuation Procedure

Wiring Connections

Single Zone Mini-Split Wiring Guide

MWMC Unit Wiring Diagram

115 V MPC012 S4 S-*L Outdoor Unit Wiring Diagram

208230 V MPC009 S4 S-*P and MPC012 S4 S-*P Outdoor Unit Wiring Diagram

208230 V MPC018 S4 S-*P Outdoor Unit Wiring Diagram

208230 V MPC030 S4 S-*P Outdoor Unit Wiring Diagram

208230 V MLB009 S4 S-*P and MLB012 S4 S-*P Outdoor Unit Wiring Diagram

208230 V MLB018 S4 S-*P Outdoor Unit Wiring Diagram

Unit Start-Up

Adding Refrigerant for Longer Line Set

Troubleshooting

Indoor Unit Error and Status Code Display

Lists common error codes and their meanings for indoor units.

Test Run

Pre-Checks

Essential checks to perform before conducting a unit test run.

Procedure

Step-by-step guide for performing the unit test run.

Related product manuals