Troubleshooting: Burner runs continuously (too little heat).
Source Procedure Causes Correction
Too much combustion air Reduce combustion air.
Air leaks into heat exchanger
around inspection door, etc.
Correct cause of air leak.
ow
2
ess
than 10%.
Excessive draft
Adjust barometric draft con-
trol for correct draft.
Incorrect burner head adjust-
ment
Correct burner head setting.
Dirty or plugged heat exchanger
Clean heat exchanger.
r
y or p
ugge
ea
exc
anger
Readjust burner.
High smoke
readin
more
Insufficient draft Increase draft.
Combustion
ec
urner
combustion for
CO2, stack tem-
than a trace. Incorrect burner head adjust-
ment
Correct burner setting.
perature, and
Too little combustion air Increase combustion air.
smo
e
Too little blower air
Increase blower speed to
maintain proper temp. rise.
Hi
h stack tem-
Blower belt too loose (if
equipped)
Tighten blower belt.
perature is
Dirty or plugged heat exchanger Clean heat exchanger.
more
an
550
_F Net.
Dirty blower wheel Clean blower wheel.
Dirty furnace air filters Clean or replace filter.
Restricted or closed registers or
dampers
Readjust registers or damp-
ers.
Inspect fire and check
Partially plugged or defective
nozzle
Replace nozzle.
ressure
oil pressure.
Oil pressure is too low: less
than 100 psi.
Increase oil pressure top
100psi.