Page 56
FIGURE 48
Field Installed
Gas Valve
Manifold Pressure Measurement
FIGURE 49
Negative Port
Positive Port
Gas Valve
Measuring Device
Field Installed
Operating Signal (Delta P) Measurement
Black Tubing +
Red and Black Tubing or Red Tubing -
F- Proper Combustion
Furnace should operate minimum 15 minutes with correct
manifold pressure and gas flow rate before checking com
bustion. Take combustion sample beyond the flue outlet
and compare to the tables below.
TABLE 30
High Fire
SLP98DFV Unit
CO
2
%
For
Nat
CO
2
%
For
L.P.
070
6.5 - 9.0 7.7 - 10.2
090
110
The maximum carbon monoxide reading should not exceed 100 ppm.