Page 1
©2007 Lennox Industries Inc.
Corp. 0704−L2
XC14
Service Literature
Revised 07−2008
XC14 SERIES UNITS
The XC14 is a high efficiency residential split−system con-
densing unit, which features a scroll compressor and
R−410A refrigerant. XC14 units are available in sizes rang-
ing from 1 1/2 through 5 tons. The series is designed for use
with an expansion valve or RFC (approved for use with
R−410A) in the indoor unit. This manual is divided into sec-
tions which discuss the major components, refrigerant sys-
tem, charging procedure, maintenance and operation se-
quence.
Information contained in this manual is intended for use by
qualified service technicians only. All specifications are sub-
ject to change.
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, person-
al injury or loss of life. Installation and service must
be performed by a qualified installer or service
agency.
WARNING
Warranty will be voided if covered equipment is re-
moved from original installation site. Warranty will
not cover damage or defect resulting from:
Flood, wind, lightning, or installation and operation
in a corrosive atmosphere (chlorine, fluorine, salt,
recycled waste water, urine, fertilizers, or other dam-
aging chemicals).
DANGER
Shock Hazard
Remove all power at disconnect
before removing access panel.
Single phase XC14 units use single-
pole contactors. Potential
exists for electrical shock resulting
in injury or death.
Line voltage exist at all components
(even when unit is not in operation).
IMPORTANT
Operating pressures of this R−410A unit are higher
than pressures in R−22 units. Always use service
equipment rated for R410A.
TABLE OF CONTENTS
General Page 1. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Specifications / Electrical Data Page 2. . . . . . . . .
I Application Page 4. . . . . . . . . . . . . . . . . . . . . . . . .
II Unit Components Page 4. . . . . . . . . . . . . . . . . .
III Refrigeration System Page 8. . . . . . . . . . . . . . .
IV Charging Page 9. . . . . . . . . . . . . . . . . . . . . . . . .
V Service and Recovery Page 21. . . . . . . . . . . . . .
VI Maintenance Page 21. . . . . . . . . . . . . . . . . . . . . .
VII Wiring and Sequence of Operation Page 22. .
Question and Answer IconNeed help?

Do you have a question about the Lennox XC14-030 and is the answer not in the manual?

Lennox XC14-030 Specifications

General IconGeneral
TypeHeat Pump
RefrigerantR-410A
Voltage208/230V
Phase1
Cooling Capacity30, 000 BTU/h
SEER Rating16

Summary

Refrigerant System

Charging

Evacuating the System

Details the process of evacuating the system to remove noncondensables and moisture.

Superheat RFC Charging Method

Detailed steps for charging RFC units using the superheat method.

Approach TXV Charging Method

Procedure for charging TXV units using the approach method.

Subcooling TXV Charging Method

Procedure for charging TXV units using the subcooling method.

Weigh-In Method for TXV Units

Procedure for weighing in refrigerant for TXV units based on line length.

Service and Recovery

System Opening Precautions

Precautions for preventing moisture entry when opening the R-410A system.

Wiring Diagrams and Sequence of Operation